Schneider Electric EZC100N1015

Schneider Electric EZC100N1015 EasyPact EZC100N Circuit Brea

MPN EZC100N1015
Obsolete

Schneider Electric EasyPact EZC100N, EZC100N1015, 1-pole thermal-magnetic circuit breaker, 15 A rated current, 25 kA breaking capacity at 110-130 V AC, IP20, backplate mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZC100N1015 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage125 V DC conforming to IEC 60947-2 415 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 18 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch25 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C

All specifications

EZC100N1015 additional specifications
ParameterValue
Temp storage min-35 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60664-1 3 conforming to IEC 947-1
Depth60 mm
Width25 mm
Height130 mm
Mechanical life cycles13000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric EZC100N1015 is a 1-pole thermal-magnetic circuit breaker from the EasyPact EZC100N series, rated 15 A at 40 °C (15 A at 50 °C with the TM-D trip unit). It's built for distribution duty in fixed-mount panels — backplate mounted, front-connected, and toggled manually. The 25 mm width per pole keeps the rail density tight; a 13000-cycle mechanical durability means it'll outlast most panel refreshes.

The EZC100N1015 carries a 25 kA Icu at 110-130 V AC and 18 kA at 220-240 V AC per IEC 60947-2. That's the N breaking capacity code — enough for most secondary distribution panels behind a larger main breaker. At 400-415 V AC it drops to 2.5 kA, so if your line side is 400 V with high fault current, this needs upstream coordination. The 5 kA at 125 V DC (1-pole) covers DC bus or battery circuits.

Fixed backplate mount, 25 mm pitch per pole, front connections top and bottom. IP20 finger-safe terminals, pollution degree 3 rated — fine for a clean panel environment. The toggle actuator gives positive contact indication; the thermal-magnetic trip handles both overload and short-circuit without an external relay.

MPN
EZC100N1015