Skip to main content
Schneider Electric EZC250N4200

Schneider Electric EZC250N4200 EasyPact EZC250N, 200 A, 20 k

MPN EZC250N4200
Active

Schneider Electric EasyPact EZC250N, circuit breaker, EZC250N4200, 200 A, 20 kA Icu at 440 V AC, 4 poles, thermal-magnetic TM-D trip unit.

$174.44 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZC250N4200 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 125 V DC 1P conforming to IEC 60947-2 20 kA Icu at 250 V DC 2P conforming to IEC 60947-2 8 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C

All specifications

EZC250N4200 additional specifications
ParameterValue
Temp storage min-35 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60947
Depth60 mm
Width140 mm
Height165 mm
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

Rating and fit — what the specs mean for a panel build

The EZC250N4200 is a 4-pole EasyPact EZC250N circuit breaker from Schneider Electric, rated 200 A at 40 °C with a TM-D thermal-magnetic trip unit.

Designed to IEC 60947-2 and IEC 60947-1, plus JIS C8201-2-2 and GB/T 14048.2. IP20 finger-safe terminals (IEC 60529) and IK07 impact resistance (EN 50102).

Physical integration

Fixed backplate mounting, 140 mm wide × 165 mm tall × 60 mm deep — the 60 mm depth is shallow enough for most 200 mm deep enclosures, leaving room for cable bending radii behind the breaker. Front connections top and bottom; 35 mm connection pitch. Toggle handle with positive contact indication — you can visually confirm the contact state without removing the cover.

MPN
EZC250N4200