Schneider Electric EZC250N4200 — Circuit Breaker Accessories

Schneider Electric EZC250N4200 EasyPact EZC250N, 200 A, 20 k

MPNEZC250N4200
Active

Schneider Electric EasyPact EZC250N, circuit breaker, EZC250N4200, 200 A, 20 kA Icu at 440 V AC, 4 poles, thermal-magnetic TM-D trip unit.

$174.44Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

EZC250N4200 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution
EZC250N4200 — Electrical
ParameterValue
Network type (AC/DC)DC AC
Rated current [In]200 A at 40 °C
Rated operational voltage [Ue]550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description4P
EZC250N4200 — Protection & Performance
ParameterValue
Breaking capacity20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 125 V DC 1P conforming to IEC 60947-2 20 kA Icu at 250 V DC 2P conforming to IEC 60947-2 8 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 125 V DC conforming to IEC 60947-2 10 kA at 250 V DC conforming to IEC 60947-2 4 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeN
Trip unit technologyThermal-magnetic
Trip unit rating200 A at 50 °C
Trip unit nameTM-D
Protection typeShort-circuit protection Overload protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability10000 cycles
Local signallingPositive contact indication
EZC250N4200 — Mechanical
ParameterValue
Connection pitch35 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC250N
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width140 mm
Height165 mm
Depth60 mm
EZC250N4200 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to EN 50102
Pollution degree3 conforming to IEC 60947
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C
EZC250N4200 — Approvals
ParameterValue
StandardsJIS C8201-2-2 EN/IEC 60947-2 EN/IEC 60947-1 GB/T 14048.2

Product details

Rating and fit — what the specs mean for a panel build

The EZC250N4200 is a 4-pole EasyPact EZC250N circuit breaker from Schneider Electric, rated 200 A at 40 °C with a TM-D thermal-magnetic trip unit.

Designed to IEC 60947-2 and IEC 60947-1, plus JIS C8201-2-2 and GB/T 14048.2. IP20 finger-safe terminals (IEC 60529) and IK07 impact resistance (EN 50102).

Physical integration

Fixed backplate mounting, 140 mm wide × 165 mm tall × 60 mm deep — the 60 mm depth is shallow enough for most 200 mm deep enclosures, leaving room for cable bending radii behind the breaker. Front connections top and bottom; 35 mm connection pitch. Toggle handle with positive contact indication — you can visually confirm the contact state without removing the cover.

Frequently asked questions

Where can I buy EZC250N4200 and what is the lead time?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm lead-time and price.

What are the key ratings of EZC250N4200?

200 A rated current at 40 °C, 20 kA Icu at 440 V AC, 4 poles, thermal-magnetic TM-D trip unit, 690 V rated insulation voltage.

What compliance documentation does Schneider provide for EZC250N4200?

The breaker is designed to IEC 60947-2, IEC 60947-1, JIS C8201-2-2, and GB/T 14048.2. It carries IP20 and IK07 ratings. RoHS and REACH declarations are typically available from Schneider Electric's documentation portal for this series.