Specifications

EZC250N44100 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 125 V DC 1P conforming to IEC 60947-2 20 kA Icu at 250 V DC 2P conforming to IEC 60947-2 8 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C

All specifications

EZC250N44100 additional specifications
ParameterValue
Temp storage min-35 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60947
Depth60 mm
Width140 mm
Height165 mm
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The EZC250N44100 is a 4-pole EasyPact EZC250N moulded-case circuit breaker from Schneider Electric, fitted with a TM-D thermal-magnetic trip unit rated 100 A at 40 °C (100 A at 50 °C). It is a distribution-class breaker (Category A per IEC 60947-2) with a fixed backplate mount and front-facing connections — designed for panel builders who need a compact, no-frills main or feeder breaker in a 4P footprint. Rated operational voltage goes to 550 V AC 50/60 Hz and 250 V DC; insulation voltage is 690 V AC. The breaking capacity code N delivers 20 kA Icu at 440 V AC, 25 kA at 380–415 V AC, and 50 kA at 220–240 V AC — enough for most commercial and light industrial distribution boards. At 125 V DC single-pole it still holds 20 kA Icu. That keeps the BOM simple but means the 100 A rating is the only setting; if the load draw changes, the breaker itself must be swapped.

Mounts fixed to a backplate via the four screw holes — no DIN-rail clip, so plan for a dedicated mounting footprint. Dimensions are 165 mm high, 140 mm wide, 60 mm deep, with a 35 mm connection pitch on the front terminals. IP20 finger-safe protection on the front, IK07 impact resistance. The toggle handle gives positive contact indication (ON/OFF/TRIPPED) visible through the enclosure window.

Designed and tested to EN/IEC 60947-1 and -2, JIS C8201-2-2, and GB/T 14048.2. Mechanical durability is 10,000 cycles.

MPN