Skip to main content
Schneider Electric LC1F1504V7

Schneider LC1F1504V7 TeSys F Contactor, 250 A AC-1, 4 NO, 40

MPN LC1F1504V7
Obsolete

Schneider Electric TeSys F contactor, LC1F1504V7, 4-pole NO, 250 A AC-1 at ≤440 V, 400 V AC 50/60 Hz coil, plate mount, EOL lifecycle.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LC1F1504V7 key specifications
ParameterValue
Control circuit typeAC at 40...400 Hz
Main product or component typeContactor
Voltage<= 460 V DC
Coil voltage400 V AC 40...400 Hz
Insulation voltage ui1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C
Current250 A (at <40 °C) at <= 440 V AC-1
Breaking capacity1200 A conforming to IEC 60947-4-1
Utilization categoryAC-1
Temp storage max80 °C
Temp storage min-60 °C
Temp operating max60 °C
Temp operating min-40 °C

All specifications

LC1F1504V7 additional specifications
ParameterValue
Storage temperature-60...80 °C
Depth171 mm
Width200.5 mm
Height170 mm
Mechanical life cycles10 Mcycles
ApplicationResistive load
Operating time35 ms closing at Uc) 130 ms opening at Uc)
Operating temperature-40...60 °C
Permissible ambient air temperature around the device60...70 °C at Uc

Product details

TeSys F 4-Pole Contactor, 250 A AC-1 — EOL Sourcing Note

The Schneider Electric LC1F1504V7 is a TeSys F contactor with four normally-open power poles, rated 250 A in AC-1 utilisation category at ≤440 V and ≤40 °C — meaning it is sized for resistive loads such as heaters or large lighting banks, not motor starting. The 400 V AC control coil draws 770 VA inrush, holding at 8.1 VA.

Dimensions, Mounting, and Wiring

The LC1F1504V7 measures 171 mm deep by 200.5 mm wide by 170 mm high and mounts to a plate (not DIN rail). Power circuit connections accept bar (25 x 3 mm busbar), ring-terminal lugs up to 120 mm², or bolted connection; torque to 18 N·m. Control circuit uses screw-clamp terminals accepting 1 to 4 mm² flexible or solid, torqued to 1.2 N·m. IP2X front-face protection with shrouds per IEC 60529.

Designed and tested to IEC 60947-4-1, EN 60947-4-1, and JIS C8201-4-1. Rated insulation voltage 1000 V per IEC 60947-4-1, impulse withstand voltage 8 kV, overvoltage category III. Protective treatment TH for tropical environments. Operating altitude 3000 m without derating. Associated fuse rating 160 A aM or 250 A gG at ≤440 V.

MPN
LC1F1504V7