Specifications

LV847200 specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui1000 V AC 50/60 Hz
IP ratingIP30
Terminal pitch70 mm
Connection surface topFront Rear
Connection surface bottomFront Rear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Electrical life cycles3000 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 AC-23 A: 3000 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-3 AC-23 A: 6000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-3 AC-3: 6000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-3
Mechanical life cycles12500 cycles with periodic preventive maintenance
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

The LV847200 is a Schneider Electric MasterPact MTZ1 drawout circuit breaker, 3-pole, rated 630 A at 40 °C. The Icw of 42 kA for 1 second confirms it withstands delayed-tripping coordination schemes common in selectivity studies. Drawout mounting means the breaker chassis stays wired to the bus while the removable cradle isolates for maintenance or swap — no need to disconnect power cables. Category B selectivity and suitability for isolation (per EN/IEC 60947-2) mean it can serve as the main incoming device in a distribution board where coordination with downstream breakers is required.

Integration notes

The breaker ships without a control unit (specified separately). Mounting support options include rails or a base plate. IP30 enclosure protection is standard; for panel environments with higher dust or moisture ingress, consider an enclosure upgrade. Power dissipation is 55 W — factor this into enclosure thermal calculations, especially in dense switchboards where multiple breakers stack. Altitude derating applies above 2000 m.

Electrical durability is 6000 cycles at 440 V AC (AC-23A) and 3000 cycles at 690 V AC; mechanical durability is 12,500 cycles with periodic preventive maintenance. Maximum breaking time is 25 ms, closing response time 50 ms.