Schneider Electric LV848355

Schneider Electric LV848355 MasterPact MTZ3 4000 A Drawout C

MPN LV848355
Active

Schneider Electric MasterPact MTZ3, LV848355, 4P drawout circuit breaker, 4000 A rated current, H2 150 kA at 415 V AC, rear connection, without control unit.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV848355 specifications
ParameterValue
Control typePush-button
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui1000 V AC 50/60 Hz
IP ratingIP30
Terminal pitch230 mm
Connection surface topRear
Connection surface bottomRear
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-1
Mechanical life cycles10000 cycles with periodic preventive maintenance
ApplicationPower distribution protection
Operating temperature-25...70 °C

Product details

The LV848355 is a Schneider Electric MasterPact MTZ3 drawout circuit breaker, rated 4000 A at 40 °C, with H2 performance class delivering 150 kA breaking capacity at 415 V AC. It is a Category B breaker per EN/IEC 60947-2, meaning it provides selectivity (discrimination) with downstream devices — the upstream breaker stays closed during a downstream fault, keeping the rest of the bus live. The 4-pole configuration with rear connection on both sides suits it for main incoming or bus-tie positions in switchboards where cable access is from the rear. Rated operational voltage is 690 V AC 50/60 Hz, with insulation voltage rated at 1000 V AC and impulse withstand of 12 kV. Service breaking capacity (Ics) matches Icu at 150 kA up to 440 V, then derates to 130 kA at 525 V and 100 kA at 690 V.

At 690 V the Ics drops to 100 kA, still high enough for most industrial secondary-distribution applications. The making capacity (Icm) is 330 kA at 415 V, confirming the breaker can close onto a bolted fault without welding contacts. For a site engineer running a coordination study: the Icw of 100 kA for 1 s (also 100 kA for 3 s) gives headroom for delayed tripping on downstream faults, allowing the breaker nearest the fault to clear first.

Physical integration — what fits where

Drawout mounting means the breaker mechanism slides into a fixed chassis. With chassis, the depth is 403 mm, width 1016 mm, height 479 mm. Without chassis, the breaker itself is 300 mm deep, 838 mm wide, 300 mm tall. The connection pitch is 230 mm. Rear connection on both sides (upside and downside) means the bus bars or cables terminate at the back of the chassis — plan for rear-accessible cable entry in the switchboard. The breaker is supplied without a control unit, so you will need to specify the Micrologic trip unit separately.

IP30 protection — not for washdown areas. Altitude rating: 0–2000 m no derating, 2000–5000 m with derating. Standards compliance includes EN/IEC 60947-1, -2, Annex H (for selectivity), and IEC 61557-12 (for power metering).

MPN
LV848355