Skip to main content
Schneider Electric LV848355 — Circuit Breaker Accessories

Schneider Electric LV848355 MasterPact MTZ3 4000 A Drawout C

MPNLV848355
Active

Schneider Electric MasterPact MTZ3, LV848355, 4P drawout circuit breaker, 4000 A rated current, H2 150 kA at 415 V AC, rear connection, without control unit.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LV848355 — Identification
ParameterValue
Product / component typeCircuit breaker
Product nameMasterPact MTZ3
Product rangeMasterPacT
Device applicationPower distribution protection

Electrical

LV848355 — Electrical
ParameterValue
Rated current [In]4000 A at 40 °C
Rated operational voltage [Ue]690 V AC 50/60 Hz
Rated insulation voltage [Ui]1000 V AC 50/60 Hz
Rated impulse withstand voltage [Uimp]12 kV
Poles description4P

Protection & Performance

LV848355 — Protection & Performance
ParameterValue
Rated service breaking capacity [Ics]150 kA at 220/415 V AC 50/60 Hz 150 kA at 440 V AC 50/60 Hz 130 kA at 500/525 V AC 50/60 Hz 100 kA at 660/690 V AC 50/60 Hz
Suitability for isolationYes conforming to EN/IEC 60947-2
Mechanical durability10000 cycles with periodic preventive maintenance
Electrical durabilityAC-3: 6000 cycles 440/690 V AC 50/60 Hz conforming to EN/IEC 60947-3 1500 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 1500 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-2 AC-23A: 1500 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-3 AC-23A: 1500 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-3

Mechanical

LV848355 — Mechanical
ParameterValue
Connection pitch230 mm
Downside connectionRear
Upside connectionRear
Device short nameMTZ3 40 H2
Control typePush-button
Mounting modeDrawout
Mounting supportRails Base plate
WidthDrawout circuit breaker with chassis: 1016 mm Drawout circuit breaker without chassis: 838 mm
HeightDrawout circuit breaker with chassis: 479 mm Drawout circuit breaker without chassis: 300 mm
DepthDrawout circuit breaker with chassis: 403 mm Drawout circuit breaker without chassis: 300 mm

Environmental

LV848355 — Environmental
ParameterValue
IP degree of protectionIP30 conforming to EN 60529
Pollution degree3 conforming to IEC 60947-1
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-40...85 °C

Approvals

LV848355 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H IEC 61557-12

Product details

The LV848355 is a Schneider Electric MasterPact MTZ3 drawout circuit breaker, rated 4000 A at 40 °C, with H2 performance class delivering 150 kA breaking capacity at 415 V AC. It is a Category B breaker per EN/IEC 60947-2, meaning it provides selectivity (discrimination) with downstream devices — the upstream breaker stays closed during a downstream fault, keeping the rest of the bus live. The 4-pole configuration with rear connection on both sides suits it for main incoming or bus-tie positions in switchboards where cable access is from the rear. Rated operational voltage is 690 V AC 50/60 Hz, with insulation voltage rated at 1000 V AC and impulse withstand of 12 kV. Service breaking capacity (Ics) matches Icu at 150 kA up to 440 V, then derates to 130 kA at 525 V and 100 kA at 690 V.

At 690 V the Ics drops to 100 kA, still high enough for most industrial secondary-distribution applications. The making capacity (Icm) is 330 kA at 415 V, confirming the breaker can close onto a bolted fault without welding contacts. For a site engineer running a coordination study: the Icw of 100 kA for 1 s (also 100 kA for 3 s) gives headroom for delayed tripping on downstream faults, allowing the breaker nearest the fault to clear first.

Physical integration — what fits where

Drawout mounting means the breaker mechanism slides into a fixed chassis. With chassis, the depth is 403 mm, width 1016 mm, height 479 mm. Without chassis, the breaker itself is 300 mm deep, 838 mm wide, 300 mm tall. The connection pitch is 230 mm. Rear connection on both sides (upside and downside) means the bus bars or cables terminate at the back of the chassis — plan for rear-accessible cable entry in the switchboard. The breaker is supplied without a control unit, so you will need to specify the Micrologic trip unit separately.

IP30 protection — not for washdown areas. Altitude rating: 0–2000 m no derating, 2000–5000 m with derating. Standards compliance includes EN/IEC 60947-1, -2, Annex H (for selectivity), and IEC 61557-12 (for power metering).

Frequently asked questions

How do I get current pricing and availability for LV848355?

The LV848355 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the closest alternative to LV848355 in the MasterPact family?

Within the MasterPact MTZ3 range, the closest alternative would be a different performance class (e.g., H1 at 100 kA or at 200 kA) or a different sensor rating (2000 A, 2500 A, 3200 A). The LV848355 is the 4000 A H2 variant; stepping to H1 reduces breaking capacity, stepping to increases it. The drawout chassis and rear connection pattern are shared across the MTZ3 platform.

What compliance documentation does this brand provide for LV848355?

The LV848355 is certified to EN/IEC 60947-1, EN/IEC 60947-2, EN/IEC 60947-2 Annex H, and IEC 61557-12. It carries a suitability-for-isolation declaration per EN/IEC 60947-2. Specific RoHS/REACH/UL documentation should be requested at quote time as the evidence does not list those marks.

MPN
LV848355