Skip to main content
Schneider Electric LV848815

LV848815 MicroLogic 3.0 X, MasterPacT, 690 V AC, LI protecti

MPN LV848815
Active

Schneider Electric MasterPacT MicroLogic 3.0 X control unit, LV848815, LI protection, LCD display, 690 V AC, 50/60 Hz.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LV848815 specifications
ParameterValue
Display typeLCD display - 128 x 96 pixels
Trip unit typeElectronic
Main product or component typeControl unit
Voltage690 V AC, +/- 10 %
Poles4
Temp operating max70 °C
Temp operating min-35 °C
Pollution degree3 conforming to IEC 60947-1
ApplicationEquipment protection, monitoring and control
Operating temperature-25...70 °C (operating) -35 °C (for start-up of product)

Product details

The Schneider Electric LV848815 is a MicroLogic 3.0 X electronic control unit for MasterPacT circuit breakers. It provides LI protection (long-time and instantaneous short-circuit) per ANSI 49 and 50, plus integrated power metering with a 128 x 96 pixel LCD display. Rated operational voltage is 690 V AC, with measurement voltage from 145.6 to 828 V AC per phase at 50/60 Hz. The unit supports 4P and 3P configurations, including 4P 3d + OSN and 4P 4d neutral protection settings.

Metering and accuracy

The control unit measures average voltage, power factor, frequency, RMS voltage, current (Ia, Ib, Ic, In, Ig), active/reactive/apparent power, and total harmonic distortion (THD) for both voltage and current. Accuracy classes include Class 0.5 for voltage unbalance, Class 1 for active/reactive energy, and Class 2 for voltage THD. Measurement accuracy for current is ±0.5 % over the 40–1600 A range (MTZ1 frame), ±0.5 % for 40–4000 A (MTZ2), and ±0.5 % for 80–6300 A (MTZ3). Active energy accuracy is ±1 % over 10 GWh; reactive energy ±2 % over 10 GVARh.

Protection and diagnostics

The LI protection curve offers adjustable long-time pickup (Ir) from 0.4 to 1 x In in 1 A steps, with long-time delay adjustable from 12.5 to 600 s at 1.5 x Ir. Instantaneous pickup (Ii) is adjustable. Thermal memory is included, and the unit logs alarms, events, and min/max values. Diagnostic features include circuit breaker health state, tripping cause indication, contact state, and MicroLogic service life tracking. The unit supports Bluetooth 4.0 LE, NFC, and USB communication for local configuration and data retrieval.

EMC compliance includes electrostatic discharge, electromagnetic field, fast transient/burst, surge (1.2/50 µs), and conducted RF immunity per IEC 61000-4-2 through -6. Conducted and radiated emissions meet Class A of CISPR 22.

MPN
LV848815