Inrush hits 136 W (170 VA) at 20 °C, then settles to a hold-in of 5.1 W (7.5 VA). The 2.2 W heat dissipation is what you budget for enclosure thermal rise — that's the steady-state number, not the inrush spike. Mechanical durability is rated at 8 Mcycles, so this coil outlasts most contactor main poles in cyclic service.

Schneider Electric LX1D83BNE TeSys Deca Contactor Coil, 24-6
MPN LX1D83BNE
Active
Schneider Electric TeSys Deca, contactor coil module LX1D83BNE, wide-range AC/DC 24-60V, for LC1D115A-150A/3P contactors.
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026
Specifications
| Parameter | Value |
|---|---|
| Coil type | Wide range |
| Control circuit type | AC/DC |
| Main product or component type | Contactor coil |
| Coil voltage | 24...60 V AC/DC |
| Mechanical life cycles | 8 Mcycles |