Schneider Electric LX1FF084

TeSys LX1FF084 Contactor Coil, 84..100 V AC, Obsolete

MPN LX1FF084
Obsolete

Schneider Electric TeSys F series, LX1FF084 contactor coil, 84 V AC 50 Hz / 100 V AC 60 Hz, 50/60 Hz control circuit, obsolete.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LX1FF084 specifications
ParameterValue
Control circuit typeAC 50/60 Hz
Main product or component typeContactor coil
Coil voltage84 V AC 50 Hz 100 V AC 60 Hz
Temp operating max55 °C
Temp operating min-5 °C
Mechanical life cycles10 Mcycles
Operating time23...35 ms closing 5...15 ms opening
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX1FF084 is a replacement contactor coil from the Schneider Electric TeSys F range, designed for use with TeSys F contactors. It is a control circuit coil rated for 84 V AC at 50 Hz and 100 V AC at 60 Hz, with a 50/60 Hz control circuit type.

The coil is rated for 84 V AC 50 Hz / 100 V AC 60 Hz, meaning it is designed for a control supply that delivers approximately 84 V at 50 Hz line frequency or 100 V at 60 Hz. The control voltage limits are specified as drop-out at 0.35...0.55 Uc and operational at 0.85...1.1 Uc at 55 °C, so the coil will reliably pick up at 71.4 V (50 Hz) and drop out between 29.4 V and 46.2 V. This is critical for ensuring the contactor does not chatter or fail to close on a marginal supply. Inrush power draw is 550 VA at 50 Hz (cos φ 0.3) and 650 VA at 60 Hz; hold-in power is 45 VA at 50 Hz and 55 VA at 60 Hz. The inrush figure governs the sizing of the control transformer and any series protection — a transformer rated for the hold-in VA alone will saturate on the inrush peak. Heat dissipation is 12...16 W at 50 Hz, which must be considered in enclosed panel thermal calculations. Operating time is 23...35 ms closing and 5...15 ms opening, with a maximum operating rate of 2400 cycles per hour at 55 °C.

Coil technology and integration notes

The coil is supplied without a built-in suppressor module. For applications with inductive load switching or where the coil is driven by a PLC output or solid-state relay, an external RC snubber or varistor across the coil terminals is recommended to limit voltage transients and extend the life of the driving device. The average resistance is 3.73 Ω at 20 °C, and the inductance of the closed circuit is 0.49 H.

Environmental and packaging

The part is packaged as a single unit.

MPN
LX1FF084