Skip to main content
Schneider Electric LX1FF084 — Contactor & Starter Coils

TeSys LX1FF084 Contactor Coil, 84..100 V AC, Obsolete

MPNLX1FF084
Obsolete

Schneider Electric TeSys F series, LX1FF084 contactor coil, 84 V AC 50 Hz / 100 V AC 60 Hz, 50/60 Hz control circuit, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX1FF084 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX1FF
Coil technologyWithout built-in suppressor module
LX1FF084 — Electrical
ParameterValue
Control circuit voltage [Uc]84 V AC 50 Hz 100 V AC 60 Hz
Control circuit typeAC 50/60 Hz
Control circuit voltage limitsDrop-out 0.35...0.55 Uc 50/60 Hz 131 °F (55 °C)) Operational 0.85...1.1 Uc 50/60 Hz 131 °F (55 °C))
Coil resistance (avg.)3.73 Ohm 68 °F (20 °C)
Coil inductance (closed circuit)0.49 H
LX1FF084 — Power & Thermal
ParameterValue
Inrush power (VA)550 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C)) 650 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))
Hold-in power (VA)45 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C)) 55 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))
Heat dissipation12...16 W 50 Hz
LX1FF084 — Performance & Durability
ParameterValue
Operating time23...35 ms closing 5...15 ms opening
Max. operating rate2400 cyc/h 131 °F (55 °C)
Mechanical durability10 Mcycles
LX1FF084 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX1FF084 is a replacement contactor coil from the Schneider Electric TeSys F range, designed for use with TeSys F contactors. It is a control circuit coil rated for 84 V AC at 50 Hz and 100 V AC at 60 Hz, with a 50/60 Hz control circuit type.

The coil is rated for 84 V AC 50 Hz / 100 V AC 60 Hz, meaning it is designed for a control supply that delivers approximately 84 V at 50 Hz line frequency or 100 V at 60 Hz. The control voltage limits are specified as drop-out at 0.35...0.55 Uc and operational at 0.85...1.1 Uc at 55 °C, so the coil will reliably pick up at 71.4 V (50 Hz) and drop out between 29.4 V and 46.2 V. This is critical for ensuring the contactor does not chatter or fail to close on a marginal supply. Inrush power draw is 550 VA at 50 Hz (cos φ 0.3) and 650 VA at 60 Hz; hold-in power is 45 VA at 50 Hz and 55 VA at 60 Hz. The inrush figure governs the sizing of the control transformer and any series protection — a transformer rated for the hold-in VA alone will saturate on the inrush peak. Heat dissipation is 12...16 W at 50 Hz, which must be considered in enclosed panel thermal calculations. Operating time is 23...35 ms closing and 5...15 ms opening, with a maximum operating rate of 2400 cycles per hour at 55 °C.

Coil technology and integration notes

The coil is supplied without a built-in suppressor module. For applications with inductive load switching or where the coil is driven by a PLC output or solid-state relay, an external RC snubber or varistor across the coil terminals is recommended to limit voltage transients and extend the life of the driving device. The average resistance is 3.73 Ω at 20 °C, and the inductance of the closed circuit is 0.49 H.

Environmental and packaging

The part is packaged as a single unit.

Frequently asked questions

What is the closest alternative to the LX1FF084 in the TeSys F range?

No official successor order code is listed in the manufacturer's records for this part. For a direct replacement, a cross-reference against the TeSys F contactor frame size and the required control voltage (84 V AC 50 Hz / 100 V AC 60 Hz) would be needed. The LX1FF084 is a specific coil variant; a parametric search for a TeSys F coil with matching voltage and frequency ratings is the recommended approach.

What is the control voltage rating of the LX1FF084?

The coil is rated for 84 V AC at 50 Hz and 100 V AC at 60 Hz, with a control circuit type of AC 50/60 Hz.

Does the LX1FF084 include a built-in coil suppression module?

No, the coil technology is specified as 'Without built-in suppressor module'. An external suppression device (e.g., RC snubber or varistor) should be added if the coil is driven by a solid-state output or if inductive transients are a concern.

MPN
LX1FF084