Skip to main content
Schneider Electric LX9FK912

Schneider TeSys LX9FK912 specific contactor coil, 24 V DC /

MPN LX9FK912
Active

Schneider Electric TeSys F, specific contactor coil LX9FK912, 24 V DC / 27-29 V AC 50/60 Hz, 60 ms opening, 20 ms closing.

$360.00 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LX9FK912 specifications
ParameterValue
Control circuit typeAC 40...400 Hz low consumption DC low consumption
Main product or component typeSpecific contactor coil
Coil voltage24 V DC 27...29 V AC 50/60 Hz
Temp operating max55 °C
Temp operating min-5 °C
Mechanical life cycles10 Mcycles
Operating time60 ms opening 20 ms closing
Operating temperature23...131 °F (-5...55 °C)

Product details

Coil specs for the panel builder

The LX9FK912 is a TeSys F specific contactor coil — the replacement or spare coil for a TeSys F contactor frame. It accepts a dual control voltage: 24 V DC and 27-29 V AC at 50/60 Hz, so one coil covers both a 24 V DC control bus and a 24 V AC supply (the AC range sits slightly higher due to the rectified waveform). Opening time is 60 ms, closing time 20 ms — the coil pulls in fast and drops out with a deliberate delay, which matters for coordinating with upstream protection or PLC scan cycles. Heat dissipation runs 15-18.3 W, so account for that in a dense DIN-rail enclosure; adjacent components need breathing room or forced convection. The coil has no built-in suppressor module. On a DC control circuit, you will want a free-wheeling diode or varistor across the coil terminals to clamp the inductive kickback — otherwise the back-EMF can couple noise into nearby electronics or damage the PLC output driving it.

Control voltage limits and drop-out behaviour

Operational voltage range is 0.85 to 1.1 Uc at 131 °F (55 °C) — meaning the coil holds in reliably down to about 20.4 V DC and up to 26.4 V DC. Drop-out occurs between 0.3 and 0.5 Uc, so the contactor releases cleanly when the control voltage falls below roughly 7-12 V DC. This gives a predictable undervoltage release characteristic for safety circuits. Hold-in power consumption is 29 W at 68 °F (20 °C), with an inrush of 470 W at the same temperature. The inrush spike is short — the inductance of the closed circuit is 0.22 H, which limits the steady-state current once the armature seats.

MPN
LX9FK912