Schneider Electric TeSys F, specific contactor coil LX9FK912, 24 V DC / 27-29 V AC 50/60 Hz, 60 ms opening, 20 ms closing.

$360.00Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX9FK912 — Identification
ParameterValue
Product typeSpecific contactor coil
Product rangeTeSys
Device short nameLX9FK
Coil technologyWithout built-in suppressor module
LX9FK912 — Electrical
ParameterValue
Control circuit voltage [Uc]24 V DC 27...29 V AC 50/60 Hz
Control circuit typeAC 40...400 Hz low consumption DC low consumption
Control circuit voltage limitsOperational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.3...0.5 Uc 131 °F (55 °C))
Coil inductance (closed circuit)0.22 H
LX9FK912 — Power & Thermal
ParameterValue
Inrush power (W)470 W 68 °F (20 °C))
Hold-in power (W)29 W 68 °F (20 °C)
Heat dissipation15...18.3 W
LX9FK912 — Performance & Durability
ParameterValue
Operating time60 ms opening 20 ms closing
Max. operating rate3600 cyc/h 158 °F (70 °C)
Mechanical durability10 Mcycles
LX9FK912 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

Coil specs for the panel builder

The LX9FK912 is a TeSys F specific contactor coil — the replacement or spare coil for a TeSys F contactor frame. It accepts a dual control voltage: 24 V DC and 27-29 V AC at 50/60 Hz, so one coil covers both a 24 V DC control bus and a 24 V AC supply (the AC range sits slightly higher due to the rectified waveform). Opening time is 60 ms, closing time 20 ms — the coil pulls in fast and drops out with a deliberate delay, which matters for coordinating with upstream protection or PLC scan cycles. Heat dissipation runs 15-18.3 W, so account for that in a dense DIN-rail enclosure; adjacent components need breathing room or forced convection. The coil has no built-in suppressor module. On a DC control circuit, you will want a free-wheeling diode or varistor across the coil terminals to clamp the inductive kickback — otherwise the back-EMF can couple noise into nearby electronics or damage the PLC output driving it.

Control voltage limits and drop-out behaviour

Operational voltage range is 0.85 to 1.1 Uc at 131 °F (55 °C) — meaning the coil holds in reliably down to about 20.4 V DC and up to 26.4 V DC. Drop-out occurs between 0.3 and 0.5 Uc, so the contactor releases cleanly when the control voltage falls below roughly 7-12 V DC. This gives a predictable undervoltage release characteristic for safety circuits. Hold-in power consumption is 29 W at 68 °F (20 °C), with an inrush of 470 W at the same temperature. The inrush spike is short — the inductance of the closed circuit is 0.22 H, which limits the steady-state current once the armature seats.

Frequently asked questions

What is LX9FK912's listed range and category?

The LX9FK912 belongs to the TeSys range, with the internal category code US10I1222341. It is a specific contactor coil for the TeSys F contactor frame.