Skip to main content
Schneider Electric MGN25090

MGN25090 C60H MCB, 1P D-curve 40 A, 15 kA breaking

MPN MGN25090
Obsolete

Schneider Electric Multi9 C60H series, MGN25090 miniature circuit breaker, 1-pole, D-curve, 40 A rated current, 15 kA breaking capacity at 240 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN25090 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage240 V AC 50/60 Hz phase to neutral
Breaking capacity15 kA Icu at 240 V AC 50/60 Hz phase to neutral conforming to EN/IEC 60947-2 4 kA Icu at 415 V AC 50/60 Hz phase to neutral conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...80 °C

All specifications

MGN25090 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
Depth73 mm
Width18 mm
Height81 mm
Electrical life cycles10000 cycles conforming to EN/IEC 60947-2
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The MGN25090 is a 1-pole C60H miniature circuit breaker from the Multi9 range, rated 40 A at 50 °C per EN/IEC 60947-2. The D-curve magnetic trip limit of 12 x In (±20 %) means it holds through motor inrush without nuisance tripping — sized for distribution or motor feeder circuits where the starting surge exceeds 8 x In. The 15 kA Icu at 240 V AC (phase-to-neutral) is the maximum fault current it can safely interrupt; the service breaking capacity Ics is 7.5 kA (50 %) at the same voltage, so for a 240 V panel with available fault current under 7.5 kA the breaker can be reclosed after a fault without replacement. The tunnel-type terminals accept 1.5 to 35 mm² rigid or flexible conductors; tighten to 3.5 N·m. IP20 finger-safe front, pollution degree 3 rated — suitable for standard control panels, not washdown environments.

The suitability-for-isolation marking (visible ON/OFF indication and contact position indicator) means it can serve as a disconnecting means per the standard — no separate isolator needed upstream in a 240 V single-phase feeder.

MPN
MGN25090