Skip to main content
Schneider Electric MGN60589

MGN60589 C60N MCB, 1P D-Curve 4A, 10kA, Multi9

MPN MGN60589
Obsolete

Schneider Electric Multi9 C60N series, MGN60589 miniature circuit-breaker, 1-pole, D-curve, 4 A rated, 10 kA breaking capacity at 240 V AC, 18 mm width.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN60589 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage240 V AC 50/60 Hz phase to neutral
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...80 °C
Pollution degree3 conforming to EN/IEC 60947-2

All specifications

MGN60589 additional specifications
ParameterValue
Depth73 mm
Width18 mm
Height81 mm
Electrical life cycles10000 cycles conforming to EN/IEC 60947-2
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The MGN60589 is a 1-pole C60N miniature circuit-breaker from the Multi9 range, rated 4 A with a D tripping curve. The D curve means the magnetic trip fires at 12 x In (±20 %) — so between 38.4 A and 57.6 A for a short-circuit or heavy inrush — making it the right choice for loads with a high starting surge like small motors, transformers, or solenoid banks where a B or C curve would nuisance-trip on startup. Breaking capacity is 10 kA Icu at 240 V AC phase-to-neutral per EN/IEC 60947-2, which covers most commercial and light industrial panel fault levels at that voltage; at 415 V AC the Icu drops to 3 kA, so if your line side is 400 V three-phase you need to check the available fault current against that lower figure. The service breaking capacity Ics is 75 % of Icu (7.5 kA at 240 V, 2.25 kA at 415 V), meaning it can safely clear and be reclosed after a fault at those levels — not just a one-shot clearance.

Depth is 73 mm, height 81 mm. The toggle gives local ON/OFF indication and a contact position indicator confirms the state of the moving contacts — useful during panel commissioning or fault isolation.

MPN
MGN60589