Skip to main content
Schneider Electric MGN60589 — 1-Pole MCB (DIN Rail)

MGN60589 C60N MCB, 1P D-Curve 4A, 10kA, Multi9

MPNMGN60589
Obsolete

Schneider Electric Multi9 C60N series, MGN60589 miniature circuit-breaker, 1-pole, D-curve, 4 A rated, 10 kA breaking capacity at 240 V AC, 18 mm width.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGN60589 — Identification
ParameterValue
Product nameC60
Product / component typeMiniature circuit-breaker
Product rangeMulti9
Device short nameC60N
Poles description1P
Number of protected poles1
Device applicationDistribution
MGN60589 — Electrical & Protection
ParameterValue
Rated current (In)4 A at 50 °C conforming to EN/IEC 60947-2
Rated operational voltage (Ue)240 V AC 50/60 Hz phase to neutral
Tripping curve codeD
Magnetic tripping limit12 x In +/- 20 %
Breaking capacity (Icu / AIR)10 kA Icu at 240 V AC 50/60 Hz phase to neutral conforming to EN/IEC 60947-2 3 kA Icu at 415 V AC 50/60 Hz phase to neutral conforming to EN/IEC 60947-2
Network type (AC/DC)AC
Network frequency50/60 Hz
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
MGN60589 — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Width18 mm
Height81 mm
Depth73 mm
Tightening torque (by circuit)Power circuit: 2 N.m
MGN60589 — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to EN/IEC 60947-2
MGN60589 — Approvals
ParameterValue
Conformity standardsEN/IEC 60947-2

Product details

The MGN60589 is a 1-pole C60N miniature circuit-breaker from the Multi9 range, rated 4 A with a D tripping curve. The D curve means the magnetic trip fires at 12 x In (±20 %) — so between 38.4 A and 57.6 A for a short-circuit or heavy inrush — making it the right choice for loads with a high starting surge like small motors, transformers, or solenoid banks where a B or C curve would nuisance-trip on startup. Breaking capacity is 10 kA Icu at 240 V AC phase-to-neutral per EN/IEC 60947-2, which covers most commercial and light industrial panel fault levels at that voltage; at 415 V AC the Icu drops to 3 kA, so if your line side is 400 V three-phase you need to check the available fault current against that lower figure. The service breaking capacity Ics is 75 % of Icu (7.5 kA at 240 V, 2.25 kA at 415 V), meaning it can safely clear and be reclosed after a fault at those levels — not just a one-shot clearance.

Depth is 73 mm, height 81 mm. The toggle gives local ON/OFF indication and a contact position indicator confirms the state of the moving contacts — useful during panel commissioning or fault isolation.

Frequently asked questions

Where can I buy MGN60589 and how is it quoted?

The MGN60589 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment on your quantity and delivery window.

What is the breaking capacity of MGN60589?

The MGN60589 has a rated breaking capacity (Icu) of 10 kA at 240 V AC phase-to-neutral and 3 kA at 415 V AC phase-to-neutral, both per EN/IEC 60947-2. The service breaking capacity (Ics) is 75 % of those values.

What does the D curve mean on this breaker?

The D curve means the magnetic trip threshold is 12 x In (±20 %), so for this 4 A breaker the instantaneous trip fires between 38.4 A and 57.6 A. This suits loads with high inrush currents like small motors, transformers, or solenoid banks where a B or C curve would nuisance-trip.

MPN
MGN60589