MGN60612 C60H MCB, 1P 6A Curve C, 15 kA at 240 V AC

MPN MGN60612
Obsolete

Schneider Electric C60H Multi9 miniature circuit-breaker, 1P, 6 A rated current, Curve C, 15 kA Icu at 240 V AC, 24 kA at 60 V DC, thermal-magnetic trip, DIN-rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN60612 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage240 V AC 50/60 Hz phase to neutral 415 V AC 50/60 Hz phase to phase
Breaking capacity15 kA Icu at 240 V AC 50/60 Hz phase to neutral conforming to EN/IEC 60947-2 4 kA Icu at 415 V AC 50/60 Hz phase to neutral conforming to EN/IEC 60947-2 24 kA Icu at 60 V DC phase to phase conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...80 °C

All specifications

MGN60612 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
Depth73 mm
Width18 mm
Height81 mm
Electrical life cycles10000 cycles conforming to EN/IEC 60947-2
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The MGN60612 is a Schneider Electric C60H miniature circuit-breaker from the Multi9 range, a single-pole thermal-magnetic MCB rated 6 A at 50 °C with a C curve (magnetic trip at 8.5 x In ±20 %). For DC circuits, the 24 kA rating at 60 V DC is unusually high for a 1P 6 A breaker — useful in battery-backed DC bus or solar combiner boxes where short-circuit current can be stiff. The C curve means the magnetic release is set to trip between 5 and 10 times rated current — here 8.5 x In ±20 %, so roughly 41–61 A instantaneous. For motor starting duty you would normally step to a D curve, but for general distribution and lightly inductive loads the C curve is the standard choice. Mounting is on a 35 mm symmetrical DIN rail — 2 module pitches (18 mm per pole) wide.

It is suitable for isolation (full contact position indicator and ON/OFF indication on the toggle). The electrical endurance is rated at 10,000 cycles under load, mechanical endurance at 20,000 cycles — consistent with a distribution-grade device expected to see occasional switching, not daily motor starts. The Ics (service breaking capacity) is 50 % of Icu at 240 V AC (7.5 kA) and 415 V AC (2 kA), and 100 % at 60 V DC (24 kA). That means after clearing a fault at the Ics level the breaker can still be used — it may not be as good as new, but it won't be destroyed. For DC circuits the 100 % rating is a strong signal: the breaker can handle repeated DC faults at its full interrupting rating without replacement.