Skip to main content
Schneider Electric MGN60617

MGN60617 C60H MCB, 1P C-curve 32 A, 15 kA at 240 V AC

MPN MGN60617
Obsolete

Schneider Electric C60H Multi9, MGN60617, 1P miniature circuit breaker, C-curve 32 A, 15 kA Icu at 240 V AC, EN/IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN60617 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage240 V AC 50/60 Hz phase to neutral 415 V AC 50/60 Hz phase to phase
Breaking capacity15 kA Icu at 240 V AC 50/60 Hz phase to neutral conforming to EN/IEC 60947-2 4 kA Icu at 415 V AC 50/60 Hz phase to neutral conforming to EN/IEC 60947-2 24 kA Icu at 60 V DC phase to phase conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...80 °C

All specifications

MGN60617 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
Depth73 mm
Width18 mm
Height81 mm
Electrical life cycles10000 cycles conforming to EN/IEC 60947-2
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The MGN60617 is a Schneider Electric C60H miniature circuit breaker from the Multi9 range — a single-pole, C-curve unit rated 32 A at 50 °C per EN/IEC 60947-2. Its 15 kA Icu at 240 V AC (phase-to-neutral) tells you it handles high prospective fault current on a 240 V distribution board without upstream fuses needing to clear first; the 24 kA Icu at 60 V DC covers battery-backed or solar-combiner circuits where DC arcs are harder to extinguish.

The C-curve trips magnetically between 5 and 10 times In (8.5 x In ±20 % here), so it's sized for general-purpose distribution — lighting, socket outlets, small motor loads with moderate inrush. The 32 A thermal-magnetic trip unit is the main selection gate: at 50 °C ambient, that's the continuous current it carries without nuisance tripping. Mounts on a standard 35 mm symmetrical DIN rail, occupies 2 x 9 mm pitches (18 mm wide), so it fits a standard 18 mm MCB slot in a distribution board.

MPN
MGN60617