MGN61813 Multi9 C60H-DC MCB, 2P, 8 A, Curve B, DC

MPN MGN61813
Obsolete

Schneider Electric Multi9 C60H-DC miniature circuit-breaker, MGN61813, 2 poles, 8 A rated current, Curve B, 20 kA breaking capacity at 220 V DC, thermal-magnetic trip, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN61813 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage250 V DC 500 V DC 220 V DC 440 V DC
Insulation voltage ui500 V DC conforming to EN/IEC 60947-2
Breaking capacity20 kA Icu at 220 V DC conforming to EN/IEC 60947-2 20 kA Icu at 250 V DC conforming to EN/IEC 60947-2 10 kA Icu at 440 V DC conforming to EN/IEC 60947-2 6 kA Icu at 500 V DC conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C

All specifications

MGN61813 additional specifications
ParameterValue
Pollution degree3 conforming to EN 60947-2
ColorGrey
Depth73 mm
Width36 mm
Height81 mm
Electrical life cycles3000 cycles L/R = 2 ms
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

DC-rated miniature circuit-breaker for distribution

The MGN61813 is a Multi9 C60H-DC miniature circuit-breaker from Schneider Electric, designed for DC distribution networks. It is a 2-pole unit rated at 8 A (at 50 °C) with a B curve magnetic tripping limit of 5.5 x In +/- 20 % DC — meaning it trips instantaneously on short-circuit currents roughly between 36 A and 53 A, protecting sensitive DC loads like control circuits and instrumentation. Breaking capacity is 20 kA Icu at 220 V DC, 20 kA at 250 V DC, 10 kA at 440 V DC, and 6 kA at 500 V DC, all per EN/IEC 60947-2. That covers most industrial DC bus voltages up to 500 V, with the 20 kA rating at 220/250 V handling high-fault scenarios in telecom or solar combiner boxes.

Clip-on mounting to DIN rail (EN 60715), 36 mm wide (4 x 9 mm pitches), 81 mm high, 73 mm deep. Occupies two standard modular slots — fits existing Multi9 distribution boards without re-spacing. IP20 finger-safe terminals; IP40 in modular enclosure. Tunnel-type terminals accept 1…25 mm² rigid stranded (AWG 18…4) or 1…16 mm² flexible, with or without ferrule. Dual and triple cable entries supported for daisy-chaining. Tightening torque 2.5 N·m; strip length 14 mm.

Rated insulation voltage (Ui) 500 V DC, operational voltage (Ue) selectable 220/250/440/500 V DC. Suitability for isolation confirmed per EN/IEC 60947-2 — can be used as a disconnecting means in DC circuits. Pollution degree 3 (industrial environment, not just clean panel). Thermal-magnetic trip unit, Category A (no intentional short-time delay). Mechanical durability 20,000 cycles, electrical durability 3,000 cycles at L/R = 2 ms. Padlockable toggle for lockout/tagout. ON/OFF indication via contact position indicator.