Schneider Electric MGN61813 — 2-Pole MCB (DIN Rail)

MGN61813 Multi9 C60H-DC MCB, 2P, 8 A, Curve B, DC

MPNMGN61813
Obsolete

Schneider Electric Multi9 C60H-DC miniature circuit-breaker, MGN61813, 2 poles, 8 A rated current, Curve B, 20 kA breaking capacity at 220 V DC, thermal-magnetic trip, clip-on DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

MGN61813 — Identification
ParameterValue
Product nameMulti9 C60H-DC
Series / familyMulti9
Device short nameC60H-DC
Product / component typeMiniature circuit-breaker
Device applicationDistribution
MGN61813 — Electrical
ParameterValue
Rated current [In]8 A at 50 °C conforming to EN/IEC 60947-2
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]250 V DC 500 V DC 220 V DC 440 V DC
Network type (AC/DC)DC
MGN61813 — Protection
ParameterValue
Tripping curve codeB
Magnetic tripping limit5.5 x In +/- 20 % DC
Breaking capacity (Icu)20 kA Icu at 220 V DC conforming to EN/IEC 60947-2 20 kA Icu at 250 V DC conforming to EN/IEC 60947-2 10 kA Icu at 440 V DC conforming to EN/IEC 60947-2 6 kA Icu at 500 V DC conforming to EN/IEC 60947-2
Rated service breaking capacity [Ics]15 kA 75 % conforming to EN/IEC 60947-2 - 220 V DC 15 kA 75 % conforming to EN/IEC 60947-2 - 250 V DC 7.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V DC 4.5 kA 75 % conforming to EN/IEC 60947-2 - 500 V
Suitable for isolationYes conforming to EN/IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
MGN61813 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height81 mm
Depth73 mm
Mounting supportDIN rail
Mounting modeClip-on
Terminal connectionsTunnel type terminal (top or bottom)1...25 mm² (AWG 18...AWG 4) - rigid stranded Tunnel type terminal (top or bottom)1...16 mm² (AWG 18...AWG 6) - flexible Tunnel type terminal (top or bottom)1...16 mm² (AWG 18...AWG 6) - flexible with ferrule Tunnel type terminal (top or bottom) - 2 cable(s) 1...10 mm² (AWG 18...AWG 8) - rigid stranded Tunnel type terminal (top or bottom) - 2 cable(s) 1...10 mm² (AWG 18...AWG 8) - flexible Tunnel type terminal (top or bottom) - 2 cable(s) 1...10 mm² (AWG 18...AWG 8) - flexible with ferrule Tunnel type terminal (top or bottom) - 3 cable(s) 1 mm² (AWG 18) - flexible stranded
Terminal tightening torque2.5 N.m top or bottom
Local signalling / indicationON/OFF indication
Contact position indicatorYes
MGN61813 — Environmental
ParameterValue
Operating temperature range-25...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
MGN61813 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2

Product details

DC-rated miniature circuit-breaker for distribution

The MGN61813 is a Multi9 C60H-DC miniature circuit-breaker from Schneider Electric, designed for DC distribution networks. It is a 2-pole unit rated at 8 A (at 50 °C) with a B curve magnetic tripping limit of 5.5 x In +/- 20 % DC — meaning it trips instantaneously on short-circuit currents roughly between 36 A and 53 A, protecting sensitive DC loads like control circuits and instrumentation. Breaking capacity is 20 kA Icu at 220 V DC, 20 kA at 250 V DC, 10 kA at 440 V DC, and 6 kA at 500 V DC, all per EN/IEC 60947-2. That covers most industrial DC bus voltages up to 500 V, with the 20 kA rating at 220/250 V handling high-fault scenarios in telecom or solar combiner boxes.

Clip-on mounting to DIN rail (EN 60715), 36 mm wide (4 x 9 mm pitches), 81 mm high, 73 mm deep. Occupies two standard modular slots — fits existing Multi9 distribution boards without re-spacing. IP20 finger-safe terminals; IP40 in modular enclosure. Tunnel-type terminals accept 1…25 mm² rigid stranded (AWG 18…4) or 1…16 mm² flexible, with or without ferrule. Dual and triple cable entries supported for daisy-chaining. Tightening torque 2.5 N·m; strip length 14 mm.

Rated insulation voltage (Ui) 500 V DC, operational voltage (Ue) selectable 220/250/440/500 V DC. Suitability for isolation confirmed per EN/IEC 60947-2 — can be used as a disconnecting means in DC circuits. Pollution degree 3 (industrial environment, not just clean panel). Thermal-magnetic trip unit, Category A (no intentional short-time delay). Mechanical durability 20,000 cycles, electrical durability 3,000 cycles at L/R = 2 ms. Padlockable toggle for lockout/tagout. ON/OFF indication via contact position indicator.

Frequently asked questions

Where can I buy MGN61813 and what is the lead time?

Sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is MGN61813's breaking capacity at 220 V DC?

20 kA Icu at 220 V DC per EN/IEC 60947-2, also 20 kA at 250 V DC, 10 kA at 440 V DC, and 6 kA at 500 V DC.

What is the closest alternative to MGN61813 in the same family?