Skip to main content
Schneider Electric MGN61814

Schneider Electric MGN61814 Multi9 C60H-DC MCB, 10A Curve B

MPN MGN61814
Obsolete

Schneider Electric Multi9 C60H-DC, MGN61814, miniature circuit breaker, 2-pole DC, 10 A, curve B, 20 kA breaking capacity at 220 V DC, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN61814 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage250 V DC 500 V DC 220 V DC 440 V DC
Insulation voltage ui500 V DC conforming to EN/IEC 60947-2
Breaking capacity20 kA Icu at 220 V DC conforming to EN/IEC 60947-2 20 kA Icu at 250 V DC conforming to EN/IEC 60947-2 10 kA Icu at 440 V DC conforming to EN/IEC 60947-2 6 kA Icu at 500 V DC conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C

All specifications

MGN61814 additional specifications
ParameterValue
Pollution degree3 conforming to EN 60947-2
ColorGrey
Depth73 mm
Width36 mm
Height81 mm
Electrical life cycles3000 cycles L/R = 2 ms
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

DC-rated miniature circuit breaker for distribution panels

It's a 2-pole unit rated 10 A at 50 °C with a B tripping curve, meaning the magnetic trip activates at 5.5 x In ±20% DC — a tight window that catches short circuits fast while riding through moderate inrush on resistive loads. Breaking capacity is the headline here: 20 kA Icu at 220 V DC and 250 V DC, 10 kA at 440 V DC, and 6 kA at 500 V DC, all per EN/IEC 60947-2. Rated insulation voltage is 500 V DC, and operational voltages cover 220, 250, 440, and 500 V DC. The thermal-magnetic trip unit gives you both overload protection (thermal bimetal) and short-circuit protection (solenoid).

Clip-on mounting to DIN rail, 36 mm wide (4 x 9 mm pitches), 81 mm tall, 73 mm deep. The tunnel-type terminals accept up to 25 mm² rigid stranded (AWG 4) on top or bottom, with a 14 mm strip length and 2.5 N·m tightening torque. You can land up to three 1 mm² flexible conductors in one terminal — handy for daisy-chaining distribution. IP20 on the terminals, IP40 on the modular enclosure per IEC 60529. The toggle gives local ON/OFF indication, and the contact position indicator confirms the state. Padlockable for lockout/tagout.

MPN
MGN61814