Skip to main content
Schneider Electric MGN61814 — 2-Pole MCB (DIN Rail)

Schneider Electric MGN61814 Multi9 C60H-DC MCB, 10A Curve B

MPNMGN61814
Obsolete

Schneider Electric Multi9 C60H-DC, MGN61814, miniature circuit breaker, 2-pole DC, 10 A, curve B, 20 kA breaking capacity at 220 V DC, clip-on DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

MGN61814 — Identification
ParameterValue
Product nameMulti9 C60H-DC
Series / familyMulti9
Device short nameC60H-DC
Product / component typeMiniature circuit-breaker
Device applicationDistribution
MGN61814 — Electrical
ParameterValue
Rated current [In]10 A at 50 °C conforming to EN/IEC 60947-2
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]250 V DC 500 V DC 220 V DC 440 V DC
Network type (AC/DC)DC
MGN61814 — Protection
ParameterValue
Tripping curve codeB
Magnetic tripping limit5.5 x In +/- 20 % DC
Breaking capacity (Icu)20 kA Icu at 220 V DC conforming to EN/IEC 60947-2 20 kA Icu at 250 V DC conforming to EN/IEC 60947-2 10 kA Icu at 440 V DC conforming to EN/IEC 60947-2 6 kA Icu at 500 V DC conforming to EN/IEC 60947-2
Rated service breaking capacity [Ics]15 kA 75 % conforming to EN/IEC 60947-2 - 220 V DC 15 kA 75 % conforming to EN/IEC 60947-2 - 250 V DC 7.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V DC 4.5 kA 75 % conforming to EN/IEC 60947-2 - 500 V
Suitable for isolationYes conforming to EN/IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
MGN61814 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height81 mm
Depth73 mm
Mounting supportDIN rail
Mounting modeClip-on
Terminal connectionsTunnel type terminal (top or bottom)1...25 mm² (AWG 18...AWG 4) - rigid stranded Tunnel type terminal (top or bottom)1...16 mm² (AWG 18...AWG 6) - flexible Tunnel type terminal (top or bottom)1...16 mm² (AWG 18...AWG 6) - flexible with ferrule Tunnel type terminal (top or bottom) - 2 cable(s) 1...10 mm² (AWG 18...AWG 8) - rigid stranded Tunnel type terminal (top or bottom) - 2 cable(s) 1...10 mm² (AWG 18...AWG 8) - flexible Tunnel type terminal (top or bottom) - 2 cable(s) 1...10 mm² (AWG 18...AWG 8) - flexible with ferrule Tunnel type terminal (top or bottom) - 3 cable(s) 1 mm² (AWG 18) - flexible stranded
Terminal tightening torque2.5 N.m top or bottom
Local signalling / indicationON/OFF indication
Contact position indicatorYes
MGN61814 — Environmental
ParameterValue
Operating temperature range-25...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
MGN61814 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2

Product details

DC-rated miniature circuit breaker for distribution panels

It's a 2-pole unit rated 10 A at 50 °C with a B tripping curve, meaning the magnetic trip activates at 5.5 x In ±20% DC — a tight window that catches short circuits fast while riding through moderate inrush on resistive loads. Breaking capacity is the headline here: 20 kA Icu at 220 V DC and 250 V DC, 10 kA at 440 V DC, and 6 kA at 500 V DC, all per EN/IEC 60947-2. Rated insulation voltage is 500 V DC, and operational voltages cover 220, 250, 440, and 500 V DC. The thermal-magnetic trip unit gives you both overload protection (thermal bimetal) and short-circuit protection (solenoid).

Clip-on mounting to DIN rail, 36 mm wide (4 x 9 mm pitches), 81 mm tall, 73 mm deep. The tunnel-type terminals accept up to 25 mm² rigid stranded (AWG 4) on top or bottom, with a 14 mm strip length and 2.5 N·m tightening torque. You can land up to three 1 mm² flexible conductors in one terminal — handy for daisy-chaining distribution. IP20 on the terminals, IP40 on the modular enclosure per IEC 60529. The toggle gives local ON/OFF indication, and the contact position indicator confirms the state. Padlockable for lockout/tagout.

Frequently asked questions

What is the breaking capacity of MGN61814 at 220 V DC?

The MGN61814 delivers 20 kA Icu at 220 V DC per EN/IEC 60947-2, with the same rating at 250 V DC, then 10 kA at 440 V DC and 6 kA at 500 V DC.

What compliance standards does MGN61814 meet?

It complies with EN/IEC 60947-2 for circuit-breaker performance, includes tropicalisation class 2 per IEC 60068-2, and carries IP20/IP40 protection per IEC 60529.

Where can I buy MGN61814 and how is it quoted?

The MGN61814 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock or price figures are published here.