MGN61860 Multi9 C60H-DC 1P DC MCB, 3 A, K Curve, 20 kA

MPN MGN61860
Obsolete

Schneider Electric Multi9 C60H-DC, miniature circuit breaker, 1P, 3 A, K curve, 20 kA Icu at 110 V DC, clip-on DIN rail mount, grey.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN61860 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage250 V DC 110 V DC 220 V DC
Insulation voltage ui500 V DC conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN 60947-2

All specifications

MGN61860 additional specifications
ParameterValue
ColorGrey
Depth73 mm
Width18 mm
Height81 mm
Electrical life cycles3000 cycles L/R = 2 ms
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

DC miniature circuit breaker for 3 A DC branch circuits

The Schneider Electric MGN61860 is a 1-pole DC miniature circuit breaker from the Multi9 C60H-DC series, rated 3 A at 50 °C per EN/IEC 60947-2. It is designed for DC distribution networks up to 250 V DC, with a K-curve magnetic trip threshold of 12 x In (±20 %) that suits loads with moderate inrush — think DC motor drives, solenoid valves, or control transformers on a DC bus. Breaking capacity is 20 kA Icu at 110 V DC, 10 kA at 220 V DC, and 6 kA at 250 V DC — all per EN/IEC 60947-2.

K curve and DC application

The K curve (12 x In magnetic trip) sits between the B and C curves in sensitivity. It is specified for DC circuits where the load draws a moderate inrush — for example, a DC power supply feeding a PLC rack or a small DC motor. The 3 A rating at 50 °C means the breaker carries 3 A continuously without nuisance tripping; above that, the thermal element responds to sustained overloads. The toggle switch provides local ON/OFF indication and is padlockable for lockout/tagout procedures.

IP20 finger protection on the front; IP40 inside the enclosure. Strip length 14 mm.