Skip to main content
Schneider Electric A9C62325

Schneider Electric A9C62325 Reflex iC60N, 25 A 3P C-curve, i

MPN A9C62325
Active

Schneider Electric Acti9 Reflex iC60N, integrated control circuit breaker, 25 A, 3P, curve C, thermal-magnetic trip, 20 kA Icu at 230 V AC.

$429.95 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9C62325 specifications
ParameterValue
Trip unit typeThermal-magnetic
Main product or component typeIntegrated control circuit breaker
Coil voltage230 V AC 50/60 Hz 24 V AC 50/60 Hz 48 V AC 50/60 Hz 24 V DC 48 V DC
Insulation voltage ui500 V AC
Breaking capacity20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
IP ratingIP20
Pollution degree3
ColorWhite
Depth77 mm
Width99 mm
Height84 mm
Electrical life cyclesAC-1: 50000 cycles AC 50 Hz
Mechanical life cycles50000 cycles
ApplicationDistribution Control

Product details

It combines overcurrent protection (thermal-magnetic trip, curve C) with local and remote switching control in a single DIN-rail module. Rated 25 A on a 3-pole (3P) network at 230 V AC, 50/60 Hz, it serves distribution and control applications where you need both a circuit breaker and a contactor in one package. The breaking capacity is 20 kA Icu at 220…240 V AC and 10 kA Icu at 380…415 V AC, per EN/IEC 60947-2.

Control and signalling

Control is via ON/OFF button, remote pulse, remote continuous command, or toggle — the control circuit accepts 24 V AC/DC, 48 V AC/DC, or 230 V AC. Local signalling includes a green LED for device ON, flashing red for tripped, and flashing for overheat or device ready. This makes fault isolation straightforward for field service: a quick visual check tells you whether the unit is healthy, tripped on overload, or thermally stressed.

Dimensions are 99 mm wide (11 x 9 mm pitches), 84 mm high, 77 mm deep. IP20 finger-safe terminals per IEC 60529; the device is padlockable in the OFF position. For a panel OEM wiring this into a control cabinet, the 77 mm depth leaves clearance under a standard 120 mm deep enclosure gland plate — no need to oversize the box.

Pollution degree 3 (industrial environment with conductive or dry non-conductive pollution). Tropicalisation class 2. Relative humidity tolerance of 93 % at 40 °C. The device accepts separate earth-leakage protection block. These specs support qualification for controlled environments: the thermal-magnetic trip curve is fixed, no firmware auto-update, so the protection profile is stable under change control.

MPN