Skip to main content
Schneider Electric A9C66425

Schneider Electric A9C66425 Reflex iC60H, 25 A, 4P, Curve D

MPN A9C66425
Obsolete

Schneider Electric Acti9 Reflex iC60H, integrated control circuit breaker, 25 A, 4P, curve D, 30 kA Icu at 240 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9C66425 specifications
ParameterValue
Trip unit typeThermal-magnetic
Main product or component typeIntegrated control circuit breaker
Coil voltage230 V AC 50/60 Hz 24 V AC 50/60 Hz 48 V AC 50/60 Hz 24 V DC 48 V DC
Insulation voltage ui500 V AC
Breaking capacity30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
IP ratingIP20
Pollution degree3
ColorWhite
Depth77 mm
Width117 mm
Height84 mm
Electrical life cyclesAC-1: 50000 cycles AC 50 Hz
Mechanical life cycles50000 cycles
ApplicationDistribution Control

Product details

Rated at 25 A with a D curve, it handles high inrush loads typical of motor and transformer circuits without nuisance tripping, while the 4-pole configuration (4P) switches all phases and neutral. Breaking capacity is 30 kA Icu at 220…240 V AC and 15 kA Icu at 380…415 V AC, both per EN/IEC 60947-2 — sufficient for most commercial and light industrial panelboards where fault levels stay below those thresholds.

Control and integration

The control circuit accepts multiple voltage options — 230 V AC, 24 V AC, 48 V AC, 24 V DC, or 48 V DC — and supports maintained, impulse, or maintained very-low-voltage signals, so it adapts to both building-management and PLC-driven schemes. Local signalling includes a green LED for ON status, a flashing LED for tripped or overheat conditions, and a red LED for fault — enough diagnostic feedback to clear a line-down event without opening the panel door.

Earth-leakage protection is handled by a separate block (not integrated), so the same breaker can be paired with a Vigi iC60 module when ground-fault detection is required. Rated insulation voltage is 500 V AC, pollution degree 3, and tropicalisation class 2 — suitable for non-condensing environments up to 93 % relative humidity at 40 °C.

MPN