Schneider Electric Acti9 iC60H, miniature circuit breaker, 4 A, B-curve, 4-pole, 70 kA Icu, clip-on rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F53404 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage12...133 V AC 50/60 Hz 220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 440 V AC 50/60 Hz <= 250 V DC
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity70 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at < 250 V DC conforming to EN/IEC 60947-2 10000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F53404 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width72 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F53404 is a 4-pole miniature circuit breaker from the Acti9 iC60H series, rated 4 A with a B-curve trip characteristic. The B-curve magnetic trip operates at 4 x In (±20 %). Breaking capacity is the headline number here: 70 kA Icu at 415 V AC per IEC 60947-2, and 10 kA Icn at the same voltage per IEC 60898-1. The 10 kA Icn is the rating for residential-style applications under the domestic standard; the 70 kA Icu is the industrial rating that matters for commercial and industrial distribution boards.

Clip-on mounting to a standard DIN rail, 4-pole width at 9 mm per pole (8 pitches total, so 72 mm wide). Depth is 78.5 mm, height 85 mm. Terminals accept 1–25 mm² rigid or 1–16 mm² flexible copper, with a tightening torque of 2 N·m. Earth-leakage protection is handled by a separate block (not integrated), so if you need RCD functionality, you add a compatible Vigi iC60 module downstream. The breaker itself is padlockable for lockout/tagout procedures.