Obsolete

Schneider Electric TeSys Deca LX1D6GG5, contactor coil, 155 V AC 50 Hz, for 80..95 A contactor, 6...10 W heat dissipation, 10 Mcycles mechanical durability.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LX1D6GG5 specifications
ParameterValue
Control circuit typeAC 50 Hz
Main product or component typeContactor coil
Coil voltage155 V AC 50 Hz
Temp operating max60 °C
Temp operating min-5 °C
Mechanical life cycles10 Mcycles
Operating temperature23...140 °F (-5...60 °C)

Product details

The LX1D6GG5 is a replacement contactor coil from the TeSys Deca range, wound for 155 V AC 50 Hz control circuits. It is designed to fit TeSys Deca contactors rated 80 through 95 A — the coil that pulls in and holds the main power contacts. The coil draws 200 VA inrush at 50 Hz (cos φ 0.75) and holds at 20 VA (cos φ 0.3). Heat dissipation runs 6 to 10 W at 50/60 Hz, so panel builders should account for that thermal load when grouping multiple contactors in a confined enclosure. The coil has no built-in suppressor module — if your application requires surge suppression, you will need to add an external RC snubber or varistor across the coil terminals.

Because there is no direct replacement from the manufacturer, a redesign or substitution review is the recommended long-term fix. If you need a drop-in coil for an existing panel, the surplus channel is your option; for new builds, plan to select a current-production coil from the TeSys range that matches your control voltage and contactor frame.

Control circuit voltage and operating limits

The control circuit is rated 155 V AC 50 Hz. The coil will pick up reliably between 0.8 and 1.1 Uc at 50 Hz (124 to 170.5 V) and will drop out between 0.3 and 0.6 Uc (46.5 to 93 V). At 60 Hz the pickup range shifts to 0.85 to 1.1 Uc (131.75 to 170.5 V). These limits apply at ambient temperatures up to 55 °C. The coil's average resistance is 63.01 Ω at 20 °C. The hold-in power consumption of 20 VA means the coil stays cool during continuous duty, but the 200 VA inrush spike should be factored into control transformer sizing if multiple coils pull in simultaneously.

MPN