Skip to main content
Schneider Electric A9N1P02DGN

Schneider Electric A9N1P02DGN Acti9 MCB, 2A D-Curve, 1P, 10k

MPN A9N1P02DGN
Active

Schneider Electric Acti9 xC60 miniature circuit breaker, A9N1P02DGN, 2 A rated current, D-curve, 1-pole, 10 kA breaking capacity, clip-on 35 mm DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N1P02DGN key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage220...240 V AC 50/60 Hz
Breaking capacity10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...85 °C
Pollution degree3

All specifications

A9N1P02DGN additional specifications
ParameterValue
ColorWhite
Depth77.5 mm
Width18 mm
Height85 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The Schneider Electric A9N1P02DGN is a 2 A, D-curve miniature circuit breaker from the Acti9 xC60 range, designed for distribution applications where high inrush currents are expected — motor, transformer, or lighting ballast loads that would nuisance-trip a C-curve device. Its thermal-magnetic trip unit responds to sustained overloads via the bimetal element and to short-circuit faults via the solenoid, with magnetic tripping set at 10 to 14 times In (20 to 28 A). The 10 kA breaking capacity at 240 V AC (IS/IEC 60898-1) means it can safely interrupt fault currents up to that level without welding contacts or cascading upstream — essential for coordination in a panel fed by a transformer with moderate fault current.

The 18 mm width occupies two 9 mm pitches — a single-pole breaker that fits a standard modular enclosure slot. Depth of 77.5 mm and height of 85 mm leave clearance for wiring and cover. Tunnel-type terminals accept up to 25 mm² rigid or 16 mm² flexible conductors; wire stripping length is 13 mm for top or bottom connection. IP20 finger-safe protection is standard for panel-mount breakers — no additional shrouding needed inside a closed enclosure.

MPN