Skip to main content
Schneider Electric A9N1P32CGN

Schneider Electric A9N1P32CGN Acti9 xC60 MCB, 32 A, C-Curve,

MPN A9N1P32CGN
Active

Schneider Electric Acti9 xC60 miniature circuit breaker, 1-pole, 32 A, C-curve, 10 kA breaking capacity, IS/IEC 60898-1, for 35 mm DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N1P32CGN key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage220...240 V AC 50/60 Hz
Breaking capacity10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...85 °C
Pollution degree3

All specifications

A9N1P32CGN additional specifications
ParameterValue
ColorWhite
Depth77.5 mm
Width18 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The Schneider Electric A9N1P32CGN is a 1-pole Acti9 xC60 miniature circuit breaker rated at 32 A with a C-curve magnetic trip characteristic (5...10 x In). Breaking capacity is 10 kA Icn at 240 V AC, certified to IS/IEC 60898-1, which covers the standard for household and similar installations in India and other IEC markets.

A B-curve would trip too early on those loads; a D-curve would let them ride through but might not clear a hard fault fast enough. Thermal-magnetic trip technology handles both overload (thermal bimetal, slow response) and short-circuit (magnetic solenoid, instantaneous). Overvoltage category IV confirms it's suitable for the main distribution point, not just downstream sub-circuits.

The Biconnect tunnel terminals at the bottom accept up to 25 mm² flexible or 35 mm² rigid cable — that's generous for a 32 A breaker and makes it straightforward to land larger tails or loop through. Wire stripping length is 13 mm for top or bottom connection. The toggle gives clear ON/OFF indication and a contact position indicator shows the actual state of the contacts, not just the handle position — useful during commissioning when you need to confirm isolation visually.

MPN
A9N1P32CGN