Skip to main content
Schneider Electric ENW13203

Schneider Electric ENW13203 EasyPact NW Circuit Breaker, 100

MPN ENW13203
Active

Schneider Electric EasyPact NW, ENW13203, 3P drawout circuit breaker, 1000 A at 40 °C, 66 kA Icu at 440 V AC, IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW13203 key specifications
ParameterValue
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity66 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP30
Terminal pitch70 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-5 °C
Storage temperature-40...85 °C

All specifications

ENW13203 additional specifications
ParameterValue
Pollution degreeclass 3
Depth277 mm
Width288 mm
Height322 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...70 °C

Product details

What this breaker delivers

The Schneider Electric ENW13203 is a 3-pole drawout circuit breaker from the EasyPact NW range, rated 1000 A at 40 °C with a breaking capacity of 66 kA Icu at 220...440 V AC 50/60 Hz per IEC 60947-2. It is a Category B breaker, meaning it is fully selective with upstream devices — the 50 kA Icw short-time withstand current (1 s) lets it ride through downstream faults without tripping, so only the faulted branch clears. For distribution duty, this selectivity is the difference between a single line down and a whole panel blackout.

Selectivity and coordination

Category B utilization (IEC 60947-2) with a 50 kA Icw for 1 s means this breaker coordinates cleanly with downstream MCCBs and fuses. Maximum breaking time is 35 ms; closing response hits 70 ms. For a panel OEM designing a selective distribution scheme, the 1000 A CT rating matches the frame size and the rear horizontal/vertical connection positions give flexibility in busbar layout.

Drawout mounting on a rail base plate — the breaker chassis stays fixed; the mechanism slides in and out for maintenance without disturbing power connections. Connection pitch is 70 mm without spreader, rear-connected. IP30 enclosure protection keeps tools and fingers out but expects panel-level sealing for washdown areas. Dimensions: 322 mm high, 288 mm wide, 277 mm deep — fits standard low-voltage switchgear compartments.

MPN
ENW13203