Specifications

GC2530B5 key specifications
ParameterValue
Control typeRemote control
Control circuit typeAC at 50 Hz
Main product or component typeModular contactor
Voltage<= 250 V AC
Coil voltage24 V AC 50 Hz
Insulation voltage ui500 V conforming to IEC 61095 500 V conforming to VDE 0110
Current25 A AC-7 A 8.5 A AC-7B
Breaking capacity68 A at 400 V for power circuit conforming to IEC 61095
Utilization categoryAC-7 A AC-7B
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max50 °C

All specifications

GC2530B5 additional specifications
ParameterValue
Temp operating min-5 °C
Storage temperature-40...70 °C
ColorWhite
Depth62.5 mm
Width36 mm
Height85 mm
Electrical life cyclesAC-7 A: 100000 cycles AC-7B: 100000 cycles
Mechanical life cycles1000000 cycles
ApplicationHeating Lighting Motor control
Operating time10...25 ms opening 10...30 ms closing
Operating position30°/vertical
Operating temperature-5...50 °C

Product details

Occupies 2 modules of 18 mm width on the DIN rail — 36 mm total — with a depth of 62.5 mm and height of 85 mm. That's a compact footprint for a 3-pole contactor; leaves room on the rail for an overload relay or auxiliary block. Screw-clamp terminals on both control and power circuits, torqued to 0.8 N·m. Power circuit accepts up to 6 mm² solid or 4 mm² flexible with a ferrule; control circuit takes up to 2.5 mm². The associated fuse recommendation is 25 A gL at ≤ 440 V for the power circuit. IP20 at the terminals (finger-safe per VDE 0106), IP40 inside an enclosure. The protective treatment is TC (tropicalised coating), which handles condensation in non-climate-controlled panels.

The 100,000-cycle electrical durability at AC-7A and AC-7B covers the typical life of a lighting contactor or a small motor starter in a conveyor or pump panel. The 1,000,000-cycle mechanical durability is the contactor's structural limit — you'll wear out the electrical contacts first in most switching duties. Operating time is 10 to 25 ms for opening, 10 to 30 ms for closing. That's fast enough for most control sequences but not a high-speed transfer switch — expect a few cycles of arc on break at rated current. Mechanical robustness: 10 Gn shock when open, 15 Gn when closed; vibration tolerance of 2 Gn open, 3 Gn closed across 5 to 300 Hz. That's enough for panel mounting on a machine frame or a mobile equipment platform. Maximum operating rate is 300 cycles per hour at 50 °C. If your application cycles faster than that — say a rapid-start lighting sequence — you'll need to derate or move to a larger contactor.

MPN