Skip to main content
Schneider Electric LX0FL005

Schneider Electric LX0FL005 TeSys F Contactor Coil, 48 V AC/

MPN LX0FL005
Obsolete

Schneider Electric TeSys F contactor coil, LX0FL005, 48 V AC/DC control circuit voltage, obsolete status.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LX0FL005 specifications
ParameterValue
Control circuit typeAC 50...400 Hz DC standard
Main product or component typeContactor coil
Coil voltage48 V AC 50...400 Hz 48 V DC
Mechanical life cycles1 Mcycles
Operating time50...100 ms unlatching 40...80 ms latching

Product details

The LX0FL005 is a TeSys F contactor coil from Schneider Electric, designed as the replaceable actuation coil for TeSys F contactors. It operates on a 48 V AC/DC control circuit, accepting AC from 50 to 400 Hz or DC standard supply. The coil is the service part that makes the contactor pull in and drop out, so if a contactor in the field stops engaging or drops out erratically, this is the component to swap before replacing the whole contactor assembly.

The unlatching operating time is 50 to 100 ms, and the latching time is 40 to 80 ms — this timing governs how fast the contactor closes and opens, which matters for coordinating with other devices in a motor start circuit. The maximum operating rate is 120 cycles per hour at 104 °F (40 °C), so it's not intended for high-speed jogging or rapid cycling applications; exceeding that rate will overheat the coil. Mechanical durability is rated at 1 million cycles, which is the expected life of the coil mechanism under normal switching conditions before wear-out.

Electrical characteristics for the panel

The coil has an average resistance of 0.87 Ohm in the latching state and 204 Ohm in the unlatching state, both measured at 68 °F (20 °C). The latching resistance is the holding current path once the contactor is sealed in; the unlatching resistance is the initial pull-in circuit. Control circuit voltage limits are 0.85 to 1.1 times Uc for both latching and unlatching, meaning the coil will reliably operate between about 40.8 V and 52.8 V on a 48 V nominal supply. Below that range, the contactor may chatter or fail to pick; above it risks coil burnout.

MPN
LX0FL005