Skip to main content
Schneider Electric A9C21162 — Contactors

Schneider Electric A9C21162 Acti9 iCT Contactor, 2P, 63 A AC

MPNA9C21162
Active

Schneider Electric Acti9 iCT contactor, A9C21162, 2P, 63 A AC-7A / 20 A AC-7B, 24 V AC 50 Hz coil, clip-on 35 mm DIN rail, IP20, IEC/EN 61095.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9C21162 — Identification
ParameterValue
Product / component typeContactor
A9C21162 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)250 V AC 50 Hz
A9C21162 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Operating altitude2000 m
A9C21162 — Approvals
ParameterValue
StandardsIEC/EN 61095
A9C21162 — Mechanical
ParameterValue
Width36 mm
Height85 mm
Depth73.5 mm

Product details

The Schneider Electric A9C21162 is a 2-pole contactor from the Acti9 iCT range, rated for motor, heating, and lighting loads on 250 V AC 50 Hz networks. It carries a 63 A rated operational current in AC-7A duty (resistive/motor loads with low inrush) and 20 A in AC-7B (motor loads with higher inrush), per IEC/EN 61095. The coil pulls 24 V AC at 50 Hz, with an inrush of 34 VA and a holding power of 1.6 W.

The AC-7A rating of 63 A is the one that governs most resistive and lightly inductive loads — think resistive heating banks or fan coils. If you are switching a motor, the 20 A AC-7B figure is the binding limit, not the 63 A headline. Electrical durability is 100,000 cycles at 63 A AC-7A, and 30,000 cycles at 20 A AC-7B — so the heavier the motor load, the shorter the contact life; plan spares accordingly.

The 2-pole footprint is 36 mm wide (2 modular pitches of 18 mm), which keeps panel density reasonable. Tightening torque is 0.8 N·m on the control circuit and 3.5 N·m on the power circuit.

Frequently asked questions

What are the key ratings I need to verify fit?

Rated operational current: 63 A in AC-7A, 20 A in AC-7B. Control voltage: 24 V AC 50 Hz. Rated operational voltage: 250 V AC 50 Hz. Poles: 2 NO. Mounting: clip-on 35 mm DIN rail.

What compliance standards does this contactor meet?

It is designed to IEC/EN 61095 for household and similar contactors, and EN/IEC 60947-4-1 for the higher-duty AC-1, AC-3, AC-5a, and AC-5b cycles. IP20 per IEC 60529, IP40 in a modular enclosure.

MPN
A9C21162