Schneider Electric A9C52410 — Contactors

A9C52410 Reflex iC60N 10 A 4P curve C integrated control MCB

MPNA9C52410
Obsolete

Schneider Electric Acti9 Reflex iC60N integrated control circuit breaker, A9C52410, 10 A, 4P, curve C, 20 kA Icu at 230 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9C52410 — Identification
ParameterValue
Product / component typeIntegrated control circuit breaker
Series / rangeActi9
A9C52410 — Contacts & Poles
ParameterValue
Pole configuration4P
A9C52410 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
A9C52410 — Mechanical
ParameterValue
Width117 mm
Height84 mm
Depth77 mm

Product details

The Schneider Electric A9C52410 is a Reflex iC60N integrated control circuit breaker from the Acti9 range — a 4-pole, 10 A, curve C thermal-magnetic MCB with a built-in remote control function. It combines overcurrent protection with the ability to switch the load on and off via a maintained or impulse control signal (230 V AC, 24 V AC, 48 V AC, 24 V DC, or 48 V DC control voltage options). This means a single DIN-rail device replaces a separate contactor and MCB in distribution and control panels, saving enclosure space and wiring.

Breaking capacity is 20 kA Icu at 230 V AC and 10 kA Icu at 415 V AC per EN/IEC 60947-2; that means it safely interrupts faults up to those levels without upstream fuses needing to clear first, which simplifies selectivity coordination in a 230/400 V panel. The 4 protected poles (4P) switch all live conductors, suitable for TN or IT systems where full isolation is required. Dimensions are 117 mm wide (13 x 9 mm pitches), 84 mm high, 77 mm deep — plan for 13 module widths in your enclosure layout.

Control and signalling

The integrated control accepts both maintained (continuous ON/OFF button) and impulse (pulse) commands, giving flexibility for local pushbutton or remote PLC control. A green LED indicates device ON, a flashing LED shows device ready, red LED signals fault, and flashing red indicates tripped or overheat — so you get status at a glance without a separate indicator module. Contact position indicator confirms the main contacts are open. Earth-leakage protection requires a separate Vigi block — not integrated, so plan for an additional module if RCD protection is needed.

Frequently asked questions

What are the key ratings for this part?

Rated current 10 A, curve C, 4 poles, breaking capacity 20 kA Icu at 230 V AC and 10 kA Icu at 415 V AC per EN/IEC 60947-2. Control voltage options include 230 V AC, 24 V AC, 48 V AC, 24 V DC, and 48 V DC. Dimensions: 117 mm wide (13 x 9 mm pitches), 84 mm high, 77 mm deep.

What compliance documentation is available for A9C52410?

The part is certified to EN/IEC 60947-2 for breaking capacity, carries IP20 per IEC 60529, and is part of the Acti9 range which includes CE marking. RoHS and REACH compliance documentation is provided with the shipment.

MPN