Schneider Electric A9C61310 — Contactors

Schneider Electric A9C61310 Reflex iC60N, 10 A 3P Curve B, 2

MPNA9C61310
Obsolete

Schneider Electric Acti9 Reflex iC60N, integrated control circuit breaker, 10 A, 3P, curve B, 20 kA breaking capacity at 240 V AC, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9C61310 — Identification
ParameterValue
Product / component typeIntegrated control circuit breaker
Series / rangeActi9
A9C61310 — Contacts & Poles
ParameterValue
Pole configuration3P
A9C61310 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
A9C61310 — Mechanical
ParameterValue
Width99 mm
Height84 mm
Depth77 mm

Product details

Breaking capacity is 20 kA Icu at 220–240 V AC and 10 kA at 380–415 V AC per EN/IEC 60947-2, which certifies it for industrial panel fault levels up to that range without upstream cascading. Three poles protected (3P), so it switches and protects all three phases simultaneously. Control voltage options span 24 V AC, 48 V AC, 230 V AC, 24 V DC, and 48 V DC — the 24 V DC variant is common for PLC or safety relay outputs; the 230 V AC version suits direct line-voltage control. The control type accepts maintained, impulse, or toggle signals, which gives flexibility for different remote-switching schemes. IP20 finger-safe terminals; separate earth-leakage block can be added downstream. Padlockable in the OFF position for LOTO compliance.

Where this class is used and deployment context

This is an integrated control circuit breaker — a single device that replaces a separate contactor + MCB pair in control and distribution panels. It is used where you need both remote on/off switching and overcurrent protection for a load: lighting circuits, small motor starters, resistive heating banks, or general distribution sub-circuits. The Reflex iC60N series sits in the Acti9 range, which is Schneider's modular DIN-rail platform for commercial and industrial panel building. The 10 A rating with B curve makes it suited for loads with low inrush — think lighting contactor duty or control transformer primary protection. For motor starting (higher inrush), a C or D curve would be more appropriate; this B curve will trip faster on inductive starts.

Frequently asked questions

What control voltages does this part accept?

The control circuit accepts 24 V AC, 48 V AC, 230 V AC, 24 V DC, and 48 V DC. This covers both common low-voltage PLC outputs and direct line-voltage switching.

What is the breaking capacity at 400 V?

At 380–415 V AC, the breaking capacity is 10 kA Icu per EN/IEC 60947-2. At 220–240 V AC, it is 20 kA Icu.

Can this be used for motor protection?

The B curve trips between 3 and 5 times rated current, which is fast for short circuits but may nuisance-trip on motor inrush. For motor starting duty, a C or D curve is more typical. This part is better suited for resistive or general-purpose loads with low inrush.