Skip to main content
Schneider Electric A9C61425 — Contactors

A9C61425 Reflex iC60N integrated control MCB, 25 A, 4P, curv

MPNA9C61425
Obsolete

Schneider Electric Acti9 Reflex iC60N integrated control circuit breaker, 25 A, 4P, curve B, 20 kA Icu at 240 V AC, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9C61425 — Identification
ParameterValue
Product / component typeIntegrated control circuit breaker
Series / rangeActi9
A9C61425 — Contacts & Poles
ParameterValue
Pole configuration4P
A9C61425 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
A9C61425 — Mechanical
ParameterValue
Width117 mm
Height84 mm
Depth77 mm

Product details

The Schneider Electric A9C61425 is a Reflex iC60N integrated control circuit breaker from the Acti9 range — a 4-pole, 25 A, curve B unit that combines overcurrent protection with local and remote switching in a single DIN-rail package. It is rated for control-distribution applications, meaning it handles both the protective and the on/off control function for a circuit, typically in a panel feeding a motor starter, lighting contactor, or similar load that needs operator or PLC-driven switching. Rated 25 A continuous, it breaks up to 20 kA Icu at 240 V AC and 10 kA Icu at 415 V AC, per EN/IEC 60947-2, which covers most commercial and light industrial panel fault levels.

This breaker accepts multiple control signal types: a maintained low-voltage pulse, an impulse (momentary) signal, or a maintained continuous command. The control circuit voltage options cover 230 V AC, 24 V AC, 48 V AC, 24 V DC, and 48 V DC — so it can be driven directly from a 24 V DC PLC output or a 230 V AC pushbutton station without an interposing relay. The toggle ON/OFF button on the front gives local manual override. Local signalling includes a green LED for device ON, a flashing LED for tripped or overheat conditions, and a flashing LED for device ready — useful for quick panel diagnostics without a multimeter. A contact position indicator shows whether the main contacts are open or closed.

At 117 mm wide (13 pitch units), it occupies four pole spaces plus the control module width. Depth is 77 mm, height 84 mm, so it clears most standard enclosure depths. The IP20 rating means it is intended for enclosed panels only, not washdown or outdoor exposure. Earth-leakage protection is handled by a separate block (not integrated), so if RCD protection is required, a companion Vigi iC60 or similar module must be added downstream. The 500 V AC rated insulation voltage gives headroom for 400 V line-to-line systems.

Frequently asked questions

What are the key ratings for the A9C61425?

Rated current 25 A, 4 poles, curve B (magnetic trip 3–5 x In). Breaking capacity: 20 kA Icu at 240 V AC, 10 kA Icu at 415 V AC per EN/IEC 60947-2. Control voltages: 230 V AC, 24 V AC, 48 V AC, 24 V DC, 48 V DC. Rated insulation voltage 500 V AC.

What is the closest alternative to the A9C61425?

Within the same Reflex iC60N family, the closest alternative would be a different current rating or curve code — for example, a 32 A or curve C variant. There is no pin-compatible direct replacement with identical ratings; the A9C61425 is the specific 25 A, 4P, curve B version. If a substitute is needed, verify the required current, poles, and curve against the Reflex iC60N range.

What compliance documentation is available for the A9C61425?

The breaker is certified to EN/IEC 60947-2 (breaking capacity ratings). It carries IP20 per IEC 60529. Pollution degree 3 per IEC 60664. The Acti9 range typically includes CE, UKCA, and EAC markings; specific UL/CSA listings should be confirmed from the nameplate or manufacturer declaration for the exact variant.

MPN
A9C61425