Schneider Electric A9F05306 Acti9 iC60N MCB, 6 A D Curve, 3P

MPNA9F05306
Active

Schneider Electric Acti9 iC60N, miniature circuit breaker, 6 A, D curve, 3 poles, 36 kA Icu at 12-133 V AC, DIN rail mount, thermal-magnetic trip.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

A9F05306 — Identification
ParameterValue
Product nameActi9 iC60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution

Ratings

A9F05306 — Ratings
ParameterValue
Rated current (In)6 A
Poles configuration3P
Number of protected poles3
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 180 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)AC DC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV

Protection

A9F05306 — Protection
ParameterValue
Curve codeD
Trip unit technologyThermal-magnetic
Magnetic tripping limit12 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles

Mechanical

A9F05306 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Terminal connection typeDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width54 mm
Height91 mm
Depth78.5 mm
Number of 9 mm pitches6

Environmental

A9F05306 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1

Approvals

A9F05306 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The A9F05306 is a 6 A D-curve miniature circuit breaker from the Schneider Acti9 iC60N family, 3-pole, rated for AC/DC networks. The D curve means magnetic tripping occurs at 12 x In ±20 % — that is 72 A instantaneous, ±14.4 A. The 36 kA Icu at 12-133 V AC (EN/IEC 60947-2) is the maximum short-circuit current it can safely interrupt once; at 220-240 V AC that drops to 20 kA, and at 380-415 V AC to 10 kA. For a 400 V distribution panel the Icn per EN/IEC 60898-1 is 6 kA at 400 V — that is the rated short-circuit capacity for household-type use. If your fault level at the panel exceeds 6 kA at 400 V, you need to coordinate upstream or use the higher Icu figures under the industrial standard.

Snaps onto DIN rail (mounting support per). Occupies 6 x 9 mm pitches — 54 mm wide. Overvoltage category IV means it can be installed at the service entrance or main distribution board, not just sub-panels.

Dual-certified to both EN/IEC 60898-1 (household-type MCB) and EN/IEC 60947-2 (industrial circuit-breaker). The industrial standard gives you the higher Icu ratings and category A utilization (not current-limiting for selectivity in the same way as category B). Suitability for isolation is confirmed under both standards — the contact position indicator shows open/closed state, and the trip indicator flags a thermal or magnetic trip.

Frequently asked questions

What is the breaking capacity of A9F05306 at 400 V?

Under EN/IEC 60898-1 the Icn is 6 kA at 400 V AC. Under EN/IEC 60947-2 the Icu is 10 kA at 380-415 V AC and 6 kA at 440 V AC.

Where can I buy A9F05306 and how is it quoted?

Sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
A9F05306