Schneider Electric A9F05306

Schneider Electric A9F05306 Acti9 iC60N MCB, 6 A D Curve, 3P

MPN A9F05306
Active

Schneider Electric Acti9 iC60N, miniature circuit breaker, 6 A, D curve, 3 poles, 36 kA Icu at 12-133 V AC, DIN rail mount, thermal-magnetic trip.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F05306 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F05306 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width54 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The A9F05306 is a 6 A D-curve miniature circuit breaker from the Schneider Acti9 iC60N family, 3-pole, rated for AC/DC networks. The D curve means magnetic tripping occurs at 12 x In ±20 % — that is 72 A instantaneous, ±14.4 A. The 36 kA Icu at 12-133 V AC (EN/IEC 60947-2) is the maximum short-circuit current it can safely interrupt once; at 220-240 V AC that drops to 20 kA, and at 380-415 V AC to 10 kA. For a 400 V distribution panel the Icn per EN/IEC 60898-1 is 6 kA at 400 V — that is the rated short-circuit capacity for household-type use. If your fault level at the panel exceeds 6 kA at 400 V, you need to coordinate upstream or use the higher Icu figures under the industrial standard.

Snaps onto DIN rail (mounting support per). Occupies 6 x 9 mm pitches — 54 mm wide. Overvoltage category IV means it can be installed at the service entrance or main distribution board, not just sub-panels.

Dual-certified to both EN/IEC 60898-1 (household-type MCB) and EN/IEC 60947-2 (industrial circuit-breaker). The industrial standard gives you the higher Icu ratings and category A utilization (not current-limiting for selectivity in the same way as category B). Suitability for isolation is confirmed under both standards — the contact position indicator shows open/closed state, and the trip indicator flags a thermal or magnetic trip.

MPN