Skip to main content
Schneider Electric A9F06410 — Miniature Circuit Breakers (MCB)

Schneider A9F06410 Acti9 iC60H MCB, 10 A, 4P, Curve B, 42 kA

MPNA9F06410
Active

Schneider Electric Acti9 iC60H, miniature circuit-breaker, 4P, 10 A, curve B, 42 kA Icu at 133 V AC, DIN rail mount, IP20.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

A9F06410 — Identification
ParameterValue
Product nameActi9 iC60
Product rangeActi9
Product/component typeMiniature circuit-breaker
Device applicationDistribution

Ratings

A9F06410 — Ratings
ParameterValue
Rated current (In)10 A
Poles configuration4P
Number of protected poles4
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity (Ics)21 kA 50 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 250 V DC
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to EN/IEC 60947-2
Network type (AC/DC)DC AC
Network frequency50/60 Hz
Utilisation categoryCategory A conforming to EN/IEC 60947-2
Overvoltage categoryIV

Protection

A9F06410 — Protection
ParameterValue
Curve codeB
Trip unit technologyThermal-magnetic
Magnetic tripping limit4 x In +/- 20 %
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1
Limitation class3 conforming to EN/IEC 60898-1
Electrical durability (cycles)10000 cycles
Mechanical durability (cycles)20000 cycles

Mechanical

A9F06410 — Mechanical
ParameterValue
Mounting supportDIN rail
Control typeToggle
Terminal connection typeDouble terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible
Terminal tightening torque2 N.m top or bottom
Wire stripping length14 mm for top or bottom connection
Contact position indicatorYes
Local signalling/indicationTrip indicator
Width72 mm
Height91 mm
Depth78.5 mm
Number of 9 mm pitches8

Environmental

A9F06410 — Environmental
ParameterValue
Operating ambient temperature-35...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Relative humidity95 % at 55 °C
Tropicalisation class2 conforming to IEC 60068-1

Approvals

A9F06410 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60898-1

Product details

The A9F06410 is a Schneider Acti9 iC60H miniature circuit-breaker (MCB) rated 10 A, 4-pole, curve B. At 400 V AC the Icn is 10 kA per EN/IEC 60898-1, which is the domestic/commercial rating; the higher Icu figures (30 kA at 240 V, 15 kA at 415 V) give the industrial specifier headroom for transformer-fed distribution boards. Curve B means magnetic tripping occurs at 3 to 5 times In (here 30–50 A), suited for resistive or lighting loads with low inrush — not for motor starting, which needs curve C or D. The thermal-magnetic trip unit handles overloads via a bimetal strip and short-circuits via a solenoid, no electronics to fail in high-ambient heat.

Snaps onto standard DIN rail. At 72 mm wide (4-pole, 9 mm per pitch × 8 pitches,), it occupies the same footprint as any 4P iC60 — no surprise when swapping into an existing Acti9 board. Depth 78.5 mm clears most 80 mm-deep enclosures; height 91 mm fits standard 120 mm DIN-rail backplates. IP20 finger-safe terminals are fine for enclosed panels; not rated for washdown. Tightening torque 2 N·m; strip length 14 mm.

The part carries dual certification to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (domestic/commercial), so it qualifies for both IEC 61439 switchboard assemblies and household consumer units. Overvoltage category IV means it can be installed at the service entrance, not just sub-distribution.

Frequently asked questions

What is A9F06410's breaking capacity at 400 V?

At 400 V AC the Icn per EN/IEC 60898-1 is 10 kA; the Icu per EN/IEC 60947-2 is 15 kA at 380–415 V AC and 10 kA at 440 V AC.

Where can I buy A9F06410 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.

What compliance documentation does Schneider provide for A9F06410?

The MCB is certified to EN/IEC 60947-2 and EN/IEC 60898-1, tropicalised to class 2 per IEC 60068-1, and carries pollution degree 3 per EN/IEC 60947-2. RoHS/REACH declarations are standard for the Acti9 range.

MPN