Skip to main content
Schneider Electric A9F06410

Schneider A9F06410 Acti9 iC60H MCB, 10 A, 4P, Curve B, 42 kA

MPN A9F06410
Active

Schneider Electric Acti9 iC60H, miniature circuit-breaker, 4P, 10 A, curve B, 42 kA Icu at 133 V AC, DIN rail mount, IP20.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F06410 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F06410 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width72 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The A9F06410 is a Schneider Acti9 iC60H miniature circuit-breaker (MCB) rated 10 A, 4-pole, curve B. At 400 V AC the Icn is 10 kA per EN/IEC 60898-1, which is the domestic/commercial rating; the higher Icu figures (30 kA at 240 V, 15 kA at 415 V) give the industrial specifier headroom for transformer-fed distribution boards. Curve B means magnetic tripping occurs at 3 to 5 times In (here 30–50 A), suited for resistive or lighting loads with low inrush — not for motor starting, which needs curve C or D. The thermal-magnetic trip unit handles overloads via a bimetal strip and short-circuits via a solenoid, no electronics to fail in high-ambient heat.

Snaps onto standard DIN rail. At 72 mm wide (4-pole, 9 mm per pitch × 8 pitches,), it occupies the same footprint as any 4P iC60 — no surprise when swapping into an existing Acti9 board. Depth 78.5 mm clears most 80 mm-deep enclosures; height 91 mm fits standard 120 mm DIN-rail backplates. IP20 finger-safe terminals are fine for enclosed panels; not rated for washdown. Tightening torque 2 N·m; strip length 14 mm.

The part carries dual certification to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (domestic/commercial), so it qualifies for both IEC 61439 switchboard assemblies and household consumer units. Overvoltage category IV means it can be installed at the service entrance, not just sub-distribution.

MPN
A9F06410