Schneider Electric A9N18556 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9N18556 Vigi C120 Add-on RCD, 2P 125A 30

MPNA9N18556
Active

Schneider Electric Acti9 Vigi C120 add-on residual current device, A9N18556, 2P, 125 A, 300 mA, Type A-SI, clip-on 35 mm DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

A9N18556 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage protection class / typeType A-SI (Super Immunised)
Earth-leakage trip time delaySelective
Residual-current tripping technologyVoltage independent
A9N18556 — Electrical Ratings
ParameterValue
Rated current (In)125 A
Rated operational voltage (Ue)230...415 V AC 50 Hz
Poles description2P
Network typeAC
Network frequency50 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to IEC 60947-1
Rated impulse withstand voltage (Uimp)6 kV conforming to IEC 60947-2
Device location in systemOutgoer Group incomer
Mechanical durability (operating cycles)20000 cycles
A9N18556 — Identification
ParameterValue
Product nameActi9 Vigi C120
Product / component typeAdd-on residual current device
Product range / familyActi9
Device short nameVigi C120
A9N18556 — Mechanical
ParameterValue
Mounting support35 mm symmetrical DIN rail
Mounting modeClip-on
Width in 9 mm modules7
Terminal connectionsTunnel type terminals 1...35 mm² flexible Tunnel type terminals 1...50 mm² rigid
Wire stripping length15 mm
Terminal tightening torque3.5 N.m
Width117 mm
Height95 mm
Depth73 mm
A9N18556 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...60 °C
IP degree of protectionIP20
Pollution degree3 conforming to IEC 60947-2
A9N18556 — Approvals
ParameterValue
StandardsEN 61009 IEC/EN 61009-2-1

Product details

Rated at 125 A (In) on a 230…415 V AC 50 Hz network, it provides 300 mA earth-leakage sensitivity with a selective (time-delayed) trip characteristic, so it coordinates downstream without nuisance tripping on transient leakage. The Type A-SI (Super Immunised) classification means it handles pulsed DC fault currents from electronics (rectifiers, VFDs, UPS) while resisting nuisance tripping from high-frequency leakage — a common need on modern mixed-load panels.

Clip-on mounting to a 35 mm symmetrical DIN rail — no tools needed for installation, and the 2P (two-pole) form factor occupies 7 modules of 9 mm pitch (63 mm total width). Tunnel-type terminals accept 1…35 mm² flexible or 1…50 mm² rigid cable; tighten to 3.5 N·m with a 15 mm strip length. The IP20 finger-safe enclosure suits enclosed distribution boards — not outdoor or washdown locations.

Designed and certified to EN 61009 and IEC/EN 61009-2-1 — the harmonised standard for residual-current-operated circuit-breakers with integral overcurrent protection (RCBOs) and, for this add-on block, the applicable product-specific requirements. Rated insulation voltage (Ui) of 500 V AC 50/60 Hz per IEC 60947-1, with an operating temperature range of -25…60 °C and storage from -40…60 °C.

Frequently asked questions

Where can I buy A9N18556 and what is the lead time?

The A9N18556 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the earth-leakage sensitivity and type of A9N18556?

The A9N18556 provides 300 mA earth-leakage sensitivity, Type A-SI (Super Immunised), with a selective (time-delayed) trip characteristic.

What compliance documentation does Schneider provide for A9N18556?

The A9N18556 is certified to EN 61009 and IEC/EN 61009-2-1, with a rated insulation voltage of 500 V AC per IEC 60947-1 and impulse withstand of 6 kV per IEC 60947-2. Standard Schneider documentation includes the declaration of conformity and product data sheet.