Skip to main content
Schneider Electric A9N21364 — 1-Pole MCB (DIN Rail)

Schneider Electric A9N21364 DT40N MCB, 6 A, 1P+N, Curve C, 6

MPNA9N21364
Obsolete

Schneider Electric Prodis DT40N MCB, A9N21364, 6 A, 1P+N, curve C, 6 kA Icn / 10 kA Icu, thermal-magnetic, DIN rail clip-on, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

A9N21364 — Identification
ParameterValue
Product nameDT40
Product / component typeMiniature circuit-breaker
Product rangeProdis
Device short nameDT40N
Poles description1P + N
Number of protected poles1
Device applicationDistribution
A9N21364 — Electrical & Protection
ParameterValue
Rated current (In)6 A
Rated operational voltage (Ue)230 V AC 50 Hz between phase and neutral
Tripping curve codeC
Magnetic tripping limit5...10 x In
Breaking capacity (Icu / AIR)6000 A Icn at 230 V AC 50 Hz conforming to EN/IEC 60898-1 10 kA Icu at 230...240 V AC 50 Hz conforming to IEC 60947-2
Network type (AC/DC)AC
Network frequency50 Hz
Overvoltage categoryIV
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
A9N21364 — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals downstream 0.33...10 mm² flexible Tunnel type terminals downstream 0.75...16 mm² rigid Tunnel type terminals upstream 0.33...10 mm² flexible Tunnel type terminals upstream 0.75...16 mm² rigid
Mounting supportDIN rail
Mounting modeClip-on
Width18 mm
Height81 mm
Depth78 mm
Tightening torque (by circuit)2 N.m
A9N21364 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...70 °C
IP degree of protectionIP20 conforming to IEC 60529
A9N21364 — Approvals
ParameterValue
Conformity standardsEN/IEC 60898-1 EN/IEC 60947-2
A9N21364 — Electrical
ParameterValue
[Ui] rated insulation voltage400 V AC 50 Hz
[Uimp] rated impulse withstand voltage4 kV conforming to IEC 60947-2

Product details

It protects a single pole plus neutral (1P+N) in 50 Hz AC distribution networks, using a thermal-magnetic trip unit that responds to overloads and short-circuits.

Breaking capacity and dual-standard certification

This breaker carries two breaking capacity ratings under separate standards. At 230 V AC, the Icn (rated short-circuit capacity per EN/IEC 60898-1) is 6000 A — the value used for domestic and similar installations. Under IEC 60947-2, the Icu (ultimate breaking capacity) reaches 10 kA at 230...240 V AC, which is the figure an industrial panel designer references for SCCR coordination. Dual certification means the same unit satisfies both a residential distribution board spec and a control-panel short-circuit rating, simplifying BOM consolidation.

The 18 mm width per pole — two 9 mm pitches — keeps the 1P+N assembly at 18 mm total, fitting standard distribution board spacing.

Frequently asked questions

Where can I buy A9N21364 and how do I get a price?

The A9N21364 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and delivery estimate.

What is A9N21364's breaking capacity at 230 V?

The Icn (rated short-circuit capacity per EN/IEC 60898-1) is 6000 A at 230 V AC. Under IEC 60947-2, the Icu (ultimate breaking capacity) is 10 kA at 230...240 V AC.

What standards does the A9N21364 comply with?

It is dual-certified to EN/IEC 60898-1 and EN/IEC 60947-2, covering both domestic/residential and industrial/panel applications. It also carries NF quality labeling and meets pollution degree 3 per IEC 60947-2 and tropicalisation class 2 per IEC 60068-1.

MPN