Specifications

A9P54716 — Identification
ParameterValue
Product / component typeMiniature circuit-breaker
Product nameActi9 iC40
Product rangeActi9
Device applicationDistribution
A9P54716 — Electrical
ParameterValue
Network type (AC/DC)AC
Rated current [In]16 A
Rated operational voltage [Ue]400 V AC 50/60 Hz
Rated insulation voltage [Ui]440 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated impulse withstand voltage [Uimp]4 kV conforming to EN/IEC 60947-2
Network frequency50/60 Hz
Poles description3P + N
Magnetic tripping limit5...10 x In conforming to EN/IEC 60898-1 8 x In +/- 20 % conforming to EN/IEC 60947-2
A9P54716 — Protection & Performance
ParameterValue
Breaking capacity10 kA Icu at 400 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Rated service breaking capacity [Ics]6000 A 100 % x Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 7.5 kA 75 % x Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionSeparate block
Suitability for isolationYes conforming to EN/IEC 60947-2
Mechanical durability20000 cycles
Electrical durability20000 cycles
Local signallingON/OFF indication Trip indicator
Contact position indicatorYes
A9P54716 — Mechanical
ParameterValue
Connections / terminalsTunnel type terminals top or bottom 1...10 mm² flexible Tunnel type terminals top or bottom 1...16 mm² rigid
Device short nameiC40N
Control typeToggle
Mounting modeClip-on
Mounting supportDIN rail
Usable 9 mm pitches6
Width54 mm
Height85 mm
Depth74 mm
ColourWhite
A9P54716 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3 conforming to EN/IEC 60947-2
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-40...85 °C
A9P54716 — Approvals
ParameterValue
StandardsEN/IEC 60898-1 EN/IEC 60947-2
A9P54716 — Specifications
ParameterValue
Curve codeC
Number of protected poles3

Product details

The Schneider Electric A9P54716 is a 16 A C-curve miniature circuit breaker from the Acti9 iC40N series, configured as 3P+N. It carries a dual rating to EN/IEC 60898-1 (6 kA Icn at 400 V AC) and EN/IEC 60947-2 (10 kA Icu at 400 V AC), which means it can be specified for either domestic-distribution or industrial-panel applications where the higher breaking capacity is needed for fault coordination. The thermal-magnetic trip unit provides C-curve protection (magnetic trip at 5–10× In per 60898-1, 8× In ±20% per 60947-2), suited for mixed resistive and moderate inductive loads like lighting circuits, small motor starters, and general-purpose branch protection.

Breaking capacity and dual-standard rating

The 6 kA Icn under EN/IEC 60898-1 is the domestic/commercial rating, sufficient for most final distribution circuits. Having both on one nameplate means the same part can be stocked for both job types, simplifying BOM management for an integrator who works across residential and light-industrial sites.

Clip-on mounting to DIN rail (35 mm symmetrical rail per EN 60715) with a 54 mm width (6 x 9 mm pitches). The 3P+N configuration places the neutral pole on the left, with the toggle control providing ON/OFF and trip-indicator local signalling. Tunnel-type terminals accept 1–16 mm² rigid or 1–10 mm² flexible conductors; tightening torque is 2 N·m.

Quality labels include OVE, IMQ, and AENOR. Earth-leakage protection requires a separate Vigi block — not integrated.

Frequently asked questions

Where can I buy the A9P54716 and what is the lead time?

The A9P54716 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of the A9P54716?

The A9P54716 has a dual breaking capacity rating: 10 kA Icu at 400 V AC per EN/IEC 60947-2 for industrial use, and 6 kA Icn at 400 V AC per EN/IEC 60898-1 for domestic/commercial circuits.

What standards does the A9P54716 comply with?

The A9P54716 is dual-rated to EN/IEC 60898-1 and EN/IEC 60947-2, covering both domestic and industrial application standards. It also carries OVE, IMQ, and AENOR quality labels.

What is the A9P54716's depth and width for panel layout?

The A9P54716 has a depth of 74 mm and a width of 54 mm (6 x 9 mm pitches), fitting standard DIN-rail enclosures with 3P+N spacing.