Skip to main content
Schneider Electric A9Q26225 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9Q26225 Acti9 Vigi iC60, 2P, 25 A, 500 m

MPNA9Q26225
Active

Schneider Electric Acti9 Vigi iC60, add-on residual current device, 2P, 25 A, Type A, 500 mA, instantaneous, 230...415 V AC, clip-on DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9Q26225 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)500 mA
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
Local signalling / indicationTrip indicator
A9Q26225 — Electrical Ratings
ParameterValue
Rated current (In)25 A
Rated operational voltage (Ue)230...415 V AC 50/60 Hz conforming to EN/IEC 61009-1 230...415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Poles description2P
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)6 kV conforming to IEC 60947-2
Device location in systemOutgoer
A9Q26225 — Identification
ParameterValue
Product nameActi9 Vigi iC60
Product / component typeAdd-on residual current device
Product range / familyActi9
Device short nameVigi iC60
A9Q26225 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Width in 9 mm modules3
Terminal connectionsTunnel type terminal downside for 1 cable(s) 1...25 mm² rigid without cable end Tunnel type terminal downside for 1 cable(s) 1...16 mm² flexible without cable end Tunnel type terminal downside for 1 cable(s) 1...16 mm² flexible with cable end
Wire stripping length14 mm for bottom connection
Terminal tightening torque2 N.m bottom
Width27 mm
Height91 mm
Depth73.5 mm
A9Q26225 — Environmental
ParameterValue
Operating ambient temperature-25...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-2
A9Q26225 — Approvals
ParameterValue
StandardsEN/IEC 61009-1 EN/IEC 61009-2-1

Product details

The Schneider Electric A9Q26225 is an Acti9 Vigi iC60 add-on residual current device (RCD) rated 25 A, 2-pole, Type A, with 500 mA sensitivity and instantaneous trip. It clips onto the right side of an Acti9 iC60 MCB via the plug-in connection, turning a standard branch breaker into a combined RCBO assembly — no extra wiring between the two units. The 27 mm width matches a single modular pitch on DIN rail, so it occupies one slot in the panel.

The 500 mA earth-leakage sensitivity suits equipment or fire protection on outgoing circuits. Type A detection catches pulsating DC fault currents. Voltage-independent tripping operates even if line voltage is lost. Insulation voltage is 500 V AC, and impulse withstand is 6 kV — enough for standard distribution environments.

Mounts via clip-on to DIN rail; the plug-in connection to the adjacent iC60 MCB handles the electrical link — no jumper wires needed. The bottom comb busbar is compatible, so you can feed a row of these from a common bus without individual ring terminals. IP20 on the body, IP40 inside a modular enclosure — standard for dry indoor panels.

Frequently asked questions

What is A9Q26225's listed range (Acti9) on this component line?

The A9Q26225 belongs to the Schneider Electric Acti9 range, specifically the Acti9 Vigi iC60 series of add-on residual current devices.

What compliance documentation does this brand provide for A9Q26225 (RoHS, REACH, UL, IEC)?

The A9Q26225 is designed to EN/IEC 61009-1 and EN/IEC 61009-2-1. It carries an IP20/IP40 rating per IEC 60529 and pollution degree 3 per IEC 60947-2. RoHS and REACH compliance documentation is typically available from Schneider Electric's product support portal for the Acti9 range.

MPN