Schneider Electric ATH230D11N4 — AC Drive (VFD) 480V

Schneider Electric ATH230D11N4 Altivar AC Drive, 11 kW

MPNATH230D11N4
Active

Schneider Electric Altivar ATH200 series, ATH230D11N4 AC drive, 11 kW, 3-phase, 480 V, 36.6 A line current at 380 V, 25.6 A at 500 V, cabinet mount, SIL 3 STO, integrated EMC filter.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ATH230D11N4 — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATH230
Product range / familyAltivar HVAC ATH200
ATH230D11N4 — Power & Output
ParameterValue
Motor power (kW)11 kW
Max. transient current30.5 A
Apparent power22.2 kVA at 500 V
ATH230D11N4 — Input / Supply
ParameterValue
Rated supply voltage range380...500 V - 15...10 %
Input line current36.6 A 380 V 25.6 A 500 V
ATH230D11N4 — Control & Performance
ParameterValue
Asynchronous motor control modesVoltage/frequency ratio, 5 points Flux vector control without sensor, standard Voltage/frequency ratio - Energy Saving, quadratic U/f Flux vector control without sensor - Energy Saving Voltage/frequency ratio, 2 points
Synchronous motor control modesVector control without sensor
ATH230D11N4 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated
Protection functionsLine supply phase loss drive Motor phase loss motor Line supply overvoltage and undervoltage drive Overheating protection drive Overload motor With PTC probes motor Short-circuit between motor phases drive Overcurrent between output phases and earth drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Prospective short-circuit current (Isc)22 kA
ATH230D11N4 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP20
Acoustic noise level58 dB
ATH230D11N4 — Environmental
ParameterValue
Operating ambient temperature14...122 °F (-10...50 °C) without derating 122...140 °F (50...60 °C)
Operating altitude3280.84...9842.52 ft (1000...3000 m) with current derating 1 % per 100 m
Relative humidity5...95 % without condensation or dripping water EN/IEC 60068-2-3
Storage / transport temperature-13...158 °F (-25...70 °C)
Pollution degree2
ATH230D11N4 — Approvals
ParameterValue
Certifications & markingCULus CE UKCA KC EAC ATEX RCM
Standards complianceIEC 61800-5-1 IEC 61800-3 UL 508C IEC 61800-3 environment 1 category C2 IEC 61800-3 environments 2 category C3 IEC 60721-3 IEC 61508 IEC 13849-1
ATH230D11N4 — Communication
ParameterValue
Communication protocolsModbus serial BACnet MS/TP

Product details

Safety-rated drive with SIL 3 STO

The ATH230D11N4 carries SIL 3 per IEC 61508 and PL e per ISO 13849-1 for its Safe Torque Off function — that means the drive can be wired into a safety circuit without an external contactor for the stop function, saving panel space and wiring time. The STO input is on a dedicated 24 V DC discrete input (1.5 kOhm impedance), so it's electrically isolated from the logic inputs — a detail that matters when you're separating the safety chain from the control PLC.

Fieldbus and I/O complement

Comes with a BACnet IP option card pre-installed, plus a 2-wire RS 485 port for Modbus serial or BACnet MS/TP — so it talks to both a BMS and a local PLC without extra hardware. The three analogue inputs cover voltage (0–10 V), bipolar differential (±10 V), and current (0–20 mA configurable), which covers most HVAC sensor types — duct static pressure, temperature, or CO2 — without signal conditioners. Six digital logic inputs plus a dedicated STO input; one of the logic inputs (DI5) can be programmed as a pulse input up to 30 kHz for flowmeter or encoder feedback.

Protection and environmental coverage

Built-in protection covers line phase loss, motor phase loss, overvoltage, undervoltage, overheating, motor overload (with PTC probe input), short-circuit between motor phases, and earth faults — so the drive handles most fault conditions without an external motor protection relay. Rated for pollution degree 2 and 5–95 % relative humidity without condensation, with an altitude derating starting at 1000 m (1 % per 100 m).

Approvals include cULus, CE, UKCA, KC, EAC, ATEX, and RCM — covers North America, Europe, Korea, Eurasia, and Australia for machine builders shipping globally.

Frequently asked questions

What safety functions does the ATH230D11N4 support?

The drive includes Safe Torque Off (STO) rated SIL 3 per IEC 61508 and PL e per ISO 13849-1, which allows removal of motor torque without an external safety contactor.

What approvals does the ATH230D11N4 carry?

It carries cULus, CE, UKCA, KC, EAC, ATEX, and RCM markings, covering North America, Europe, Korea, Eurasia, and Australia.

What fieldbus options are available on the ATH230D11N4?

It includes an integrated BACnet IP option card and a 2-wire RS 485 port supporting Modbus serial and BACnet MS/TP.