Skip to main content
Schneider Electric ATH630C25N4Z — AC Drive (VFD) 480V

Schneider ATH630C25N4Z Altivar 600 VFD, 400 hp ND, 480 V

MPNATH630C25N4Z
Active

Schneider Electric Altivar HVAC ATH600 series, ATH630C25N4Z AC drive, 400 hp normal duty / 300 hp heavy duty, 480 V, 451 A line current, cabinet mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ATH630C25N4Z — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATH630
Product range / familyAltivar HVAC ATH600
ATH630C25N4Z — Power & Output
ParameterValue
Motor power (kW)250 kW for normal duty 200 kW for heavy duty
Max. transient current529.1 A during 60 s (normal duty) 580.5 A during 60 s (heavy duty)
Apparent power304.3 kVA (normal duty) 250.2 kVA (heavy duty)
ATH630C25N4Z — Input / Supply
ParameterValue
Rated supply voltage range380...480 V - 15...10 %
Input line current451 A at 380 V (normal duty) 366 A at 480 V (normal duty) 365 A at 380 V (heavy duty) 301 A at 480 V (heavy duty)
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for control circuit: 24 V DC (19...30 V), Internal supply for digital inputs and STO: 24 V DC (20.4...27 V), Internal supply for reference potentiometer: 10.5 V DC +/- 5 %, <10 mA, protection type: short-circuit
ATH630C25N4Z — Control & Performance
ParameterValue
Asynchronous motor control modesVoltage/frequency ratio, 5 points Flux vector control with sensor, standard Voltage/frequency ratio - Energy Saving, quadratic U/f Flux vector control without sensor - Energy Saving Voltage/frequency ratio, 2 points
Synchronous motor control modesVector control without sensor
ATH630C25N4Z — Protection & EMC
ParameterValue
Integrated EMC filter classClass C3 EMC filter integrated
Protection functionsThermal overload protection: motor Safe torque off: motor Motor phase loss: motor Against exceeding limit speed: motor Temperature protection: drive Overheating: drive Output overcurrent between motor phase and earth: drive Output overcurrent between motor phases: drive Short-circuit between motor phase and earth: drive Short-circuit between motor phases: drive DC Bus overvoltage: drive Line supply overvoltage: drive Line supply undervoltage: drive Input supply loss: drive Break on the control circuit: drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Prospective short-circuit current (Isc)50 kA
ATH630C25N4Z — Mechanical & Cooling
ParameterValue
IP degree of protectionIP00
Acoustic noise level68 dB
ATH630C25N4Z — Environmental
ParameterValue
Operating ambient temperature-15...40 °C without derating 40...60 °C with derating factor
Operating altitude1000 m without derating 1000...3000 m with current derating 1 % per 100 m
Relative humidity5...95 % without condensation conforming to IEC 60068-2-3
Storage / transport temperature-25...70 °C
Pollution degree2
ATH630C25N4Z — Approvals
ParameterValue
Certifications & markingCE UKCA CULus EAC RCM ATEX WEEE ROHS KCC
Standards complianceUL 61800-5-1 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 RoHS
ATH630C25N4Z — Communication
ParameterValue
Communication protocolsModbus serial BACnet MS/TP

Product details

400 hp at 480 V — normal and heavy duty defined

The ATH630C25N4Z is a cabinet-mount Altivar 600 drive rated 400 hp (250 kW) for normal duty and 300 hp (200 kW) for heavy duty at 480 V. The normal-duty line current is 451 A at 380 V and 366 A at 480 V; heavy duty draws 365 A at 380 V and 301 A at 480 V. Apparent power is 304.3 kVA normal duty, 250.2 kVA heavy duty.

Safety integration and EMC compliance

Built-in STO (safe torque off) function certified to SIL 3 per IEC 61508 and PL e per ISO 13849-1, so the drive can serve in safety circuits without an external safety relay for the stop function. The integrated Class C3 EMC filter meets EN/IEC 61800-3 for second-environment (industrial) installations, meaning an external filter may be needed for residential or first-environment mains.

HVAC-specific firmware and fieldbus options

The drive includes fire mode, forced fire mode, PID controller with three additional PID loops, damper control, scroll compressor management, and catch-on-the-fly — functions that match the Altivar 600's HVAC positioning. Communication options include BACnet IP, PROFINET, and Ethernet IP/Modbus TCP via option cards, plus a built-in 2-wire RS-485 with Modbus RTU and BACnet MS/TP.

Frequently asked questions

What compliance documentation does Schneider Electric provide for ATH630C25N4Z?

The drive carries CE, UKCA, CULus, EAC, RCM, ATEX, WEEE, RoHS, and KCC markings. Standards compliance includes UL 61800-5-1, EN/IEC 61800-3, EN/IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and ISO 13849-1.

MPN
ATH630C25N4Z