Skip to main content
Schneider Electric ATV1200A6603333 — AC Drive (VFD) 480V

Schneider Electric ATV1200A6603333 AC Drive (VFD) 480V

MPNATV1200A6603333
Active

Schneider Electric Altivar 1200 ATV1200A6603333 medium-voltage AC drive, 552 kW, 660 kVA, 18-pulse diode rectifier, 2970...3630 V supply, floor-standing enclosure.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV1200A6603333 — Identification
ParameterValue
Product typeMedium voltage variable speed drive
Device short nameATV1200
Product range / familyAltivar 1200

Power & Output

ATV1200A6603333 — Power & Output
ParameterValue
Motor power (kW)552 kW
Continuous output current116 A (standard overload) 93 A (high overload)
Max. transient current139 A for 60 s
Apparent power660 kVA

Input / Supply

ATV1200A6603333 — Input / Supply
ParameterValue
Rated supply voltage range3.3 kV +/- 10 %
Input line current135 A
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)

Control & Performance

ATV1200A6603333 — Control & Performance
ParameterValue
Output frequency range0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback
Asynchronous motor control modesVector control with sensor, optional Closed-loop control with encoder Sensorless flux vector control Voltage/frequency ratio (V/f)
Synchronous motor control modesVoltage/frequency ratio (V/f) Closed-loop control with encoder

Protection & EMC

ATV1200A6603333 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated
Protection functionsGround fault protection: drive
Prospective short-circuit current (Isc)31.5 kA for 150 ms

Mechanical & Cooling

ATV1200A6603333 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP42 IP41 IP31
Acoustic noise level80 dB
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure with separate air flows

Environmental

ATV1200A6603333 — Environmental
ParameterValue
Operating ambient temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)
Operating altitude1000...2000 m with current derating 0.6 % per 100 m
Relative humidity0...90 % 0...95 % optional
Storage / transport temperature-10...60 °C
Pollution degree2 conforming to EN/IEC 61800-5-1
Vibration resistance4.9 m/s² (f= 10...50 Hz)

Approvals

ATV1200A6603333 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceEN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1

Communication

ATV1200A6603333 — Communication
ParameterValue
Communication protocolsHuman machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9

Product details

What this drive handles and where it fits

The ATV1200A6603333 is a medium-voltage Altivar 1200 drive rated for 552 kW motor power at 660 kVA apparent power, accepting a supply range of 2970...3630 V. It drives both synchronous and asynchronous motors — common for large pumps, fans, compressors, and conveyors in process plants, water treatment, and mining. The 18-pulse diode rectifier bridge on the input side draws 135 A line current and keeps harmonic distortion low enough to meet IEEE 519 without external filters in most installations. Integrated EMC filter is standard.

Overload profile and fault handling

Standard overload rating holds 1.2× In for 60 s and 1.5× In for 3 s; high overload pushes to 1.5× In for 60 s and 1.85× In for 3 s. This gives headroom for starting high-inertia loads or clearing transient overloads without tripping. The drive withstands a prospective line short-circuit current of 31.5 kA for 150 ms — enough to coordinate with upstream MV switchgear on most distribution networks. Ground-fault protection is built into the drive.

Cooling, enclosure, and installation constraints

The drive ships in a floor-standing enclosure with separate airflows for the transformer and power cells. Forced convection cooling moves 9900 m³/h (standard efficiency) or 13 200 m³/h (high efficiency). Noise level is 80 dB — plan for hearing protection if the drive is in a manned area. Dimensions: 2760 mm wide (3060 mm high-efficiency), 2520 mm tall (2670 mm high-efficiency), 1400 mm deep (1500 mm high-efficiency). Pollution degree 2 per EN/IEC 61800-5-1.

Auxiliary supplies and control wiring

The control electronics require an external 220 V AC supply at 3 kVA; the cooling fan runs on 380 V AC internal supply. Optional external supplies for both are available. Electrical isolation between power and control circuits is standard. Six discrete inputs (10 optional) and four software-configurable analogue inputs (0...20 mA / 4...20 mA, 250 Ω impedance) handle most process signals. One analogue output (same current range) is provided. Dielectric strength between earth and power terminals is 10 kV AC.

Frequently asked questions

What is ATV1200A6603333's listed depth and width?

Depth is 1400 mm (standard efficiency) or 1500 mm (high efficiency). Width is 2760 mm (standard efficiency) or 3060 mm (high efficiency). Height is 2520 mm (standard efficiency) or 2670 mm (high efficiency).

What compliance documentation does Schneider Electric provide for ATV1200A6603333?

The drive carries CE marking and is designed to EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. Overvoltage category II, pollution degree 2 per EN/IEC 61800-5-1.

MPN
ATV1200A6603333