Schneider Electric ATV1200A82506666 — AC Drive (VFD) 480V

Schneider ATV1200A82506666 AC Drive, 6897 kW, 8250 kVA

MPNATV1200A82506666
Active

Schneider Electric Altivar 1200 ATV1200A82506666 medium-voltage AC drive, 6897 kW motor power, 8250 kVA apparent power, 36-pulse diode rectifier, 2970…3630 V supply, floor-standing enclosure.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV1200A82506666 — Identification
ParameterValue
Product typeMedium voltage variable speed drive
Device short nameATV1200
Product range / familyAltivar 1200

Power & Output

ATV1200A82506666 — Power & Output
ParameterValue
Motor power (kW)6897 kW
Continuous output current720 A (standard overload) 576 A (high overload)
Max. transient current864 A for 60 s
Apparent power8250 kVA

Input / Supply

ATV1200A82506666 — Input / Supply
ParameterValue
Rated supply voltage range6.6 kV +/- 10 %
Input line current720 A
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)

Control & Performance

ATV1200A82506666 — Control & Performance
ParameterValue
Output frequency range0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback
Asynchronous motor control modesVector control with sensor, optional Sensorless flux vector control Voltage/frequency ratio (V/f) Closed-loop control with encoder
Synchronous motor control modesVoltage/frequency ratio (V/f) Closed-loop control with encoder

Protection & EMC

ATV1200A82506666 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated
Protection functionsGround fault protection: drive
Prospective short-circuit current (Isc)31.5 kA for 150 ms

Mechanical & Cooling

ATV1200A82506666 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP41 IP31 IP42
Acoustic noise level80 dB
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure with separate air flows

Environmental

ATV1200A82506666 — Environmental
ParameterValue
Operating ambient temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)
Operating altitude1000...2000 m with current derating 0.6 % per 100 m
Relative humidity0...90 % 0...95 % optional
Storage / transport temperature-10...60 °C
Pollution degree2 conforming to EN/IEC 61800-5-1
Vibration resistance4.9 m/s² (f= 10...50 Hz)

Approvals

ATV1200A82506666 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceEN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1

Communication

ATV1200A82506666 — Communication
ParameterValue
Communication protocolsHuman machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9

Product details

6897 kW drive, floor-standing — what it means on the line

The ATV1200A82506666 is a medium-voltage drive from the Altivar 1200 family, rated for 6897 kW motor power and 8250 kVA apparent power. That puts it squarely in the large-motor class — think mainline conveyors, crushers, large pumps or compressors in mining, cement, or oil-and-gas installations. Supply voltage range is 2970…3630 V, fed through a 36-pulse diode rectifier bridge. The 36-pulse topology cancels the 5th, 7th, 11th, and 13th harmonics at the input, which means you can often skip a dedicated harmonic filter at the point of common coupling — that saves panel space and transformer derating.

Physical footprint and installation constraints

This is a floor-standing enclosure, not a wall-mount. Dimensions are 3040 mm high, 9770 mm wide, and 1700 mm deep — so you need a dedicated drive room with a reinforced floor and a crane or forklift path for positioning. The enclosure has separate air flows for power and control sections, which keeps the electronics cooler and reduces dust ingress. Cooling is forced convection pulling 100,000 m³/h of air — that's substantial. The room's HVAC and louvers need to handle that airflow without recirculating hot exhaust. Operating altitude derating starts at 1000 m: 0.6 % current reduction per 100 m above that.

Overload duty and auxiliary supply architecture

The drive supports two overload profiles. Standard overload: 1.2× In for 60 s, 1.5× In for 3 s. High overload: 1.5× In for 60 s, 1.85× In for 3 s. Pick the profile that matches your load cycle — high overload covers crusher start-ups or extruder breakaway torque without oversizing the drive frame. Control electronics need an external 220 V AC supply rated at 3 kVA. The cooling fans run on a separate 380 V AC supply (also external). There's an optional 220 V AC/DC control supply. This split architecture means the control section stays live even if the main power is off — useful for pre-charge sequencing and diagnostics before the main contactor closes.

Compliance is solid: CE marked, designed to EN/IEC 61800-3 (EMC), EN/IEC 61800-4 (adjustable speed drives), and EN/IEC 61800-5-1 (electrical safety). Pollution degree 2 per the same safety standard, overvoltage category II. The integrated EMC filter means you don't need an external input filter for most installations.

Frequently asked questions

Who supplies ATV1200A82506666 and how is it quoted for volume purchases?

We source this drive through independent industrial distribution. It is quoted to order against your BOM; availability and volume pricing are confirmed at the time of RFQ. Because this is a medium-voltage drive with significant lead times, we recommend submitting a formal request with your target quantity and delivery window.

MPN
ATV1200A82506666