Skip to main content
Schneider Electric ATV1200A85506363 — AC Drive (VFD) 480V

Schneider Electric ATV1200A85506363 Altivar 1200 VFD

MPNATV1200A85506363
Active

Schneider Electric Altivar 1200 ATV1200A85506363, medium-voltage AC drive, 6571 kW motor power, 7860 kVA apparent power, 36-pulse diode rectifier, 2970–3630 V supply, floor-standing enclosure.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV1200A85506363 — Identification
ParameterValue
Product typeMedium voltage variable speed drive
Device short nameATV1200
Product range / familyAltivar 1200

Power & Output

ATV1200A85506363 — Power & Output
ParameterValue
Motor power (kW)6571 kW
Continuous output current720 A (standard overload) 576 A (high overload)
Max. transient current864 A for 60 s
Apparent power7860 kVA

Input / Supply

ATV1200A85506363 — Input / Supply
ParameterValue
Rated supply voltage range6.3 kV +/- 10 %
Input line current720 A
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)

Control & Performance

ATV1200A85506363 — Control & Performance
ParameterValue
Output frequency range0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback
Asynchronous motor control modesVoltage/frequency ratio (V/f) Closed-loop control with encoder Vector control with sensor, optional Sensorless flux vector control
Synchronous motor control modesClosed-loop control with encoder Voltage/frequency ratio (V/f)

Protection & EMC

ATV1200A85506363 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated
Protection functionsGround fault protection: drive
Prospective short-circuit current (Isc)31.5 kA for 150 ms

Mechanical & Cooling

ATV1200A85506363 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP41 IP42 IP31
Acoustic noise level80 dB
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure with separate air flows

Environmental

ATV1200A85506363 — Environmental
ParameterValue
Operating ambient temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)
Operating altitude1000...2000 m with current derating 0.6 % per 100 m
Relative humidity0...90 % 0...95 % optional
Storage / transport temperature-10...60 °C
Pollution degree2 conforming to EN/IEC 61800-5-1
Vibration resistance4.9 m/s² (f= 10...50 Hz)

Approvals

ATV1200A85506363 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceEN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1

Communication

ATV1200A85506363 — Communication
ParameterValue
Communication protocolsHuman machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9

Product details

Physical scale and installation footprint

The ATV1200A85506363: The enclosure has separate air flows for the power section and control compartment, with forced convection cooling moving 100,000 m³/h of air. The operating position is vertical ±10 degrees. Ambient conditions: 0–90 % relative humidity (0–95 % optional), altitude up to 2000 m with 0.6 % derating per 100 m above 1000 m.

Power rating and motor duty

Rated for 6571 kW motor power at 7860 kVA apparent power, drawing 720 A line current from a 2970–3630 V supply. The output voltage is equal to or less than the supply voltage. This drive is intended for large asynchronous motors — think induced-draft fans, boiler feed pumps, or mainline conveyor drives in heavy industry. Overload capability is defined in four tiers: 1.2× rated current (In) for 60 s standard duty, 1.5× In for 3 s standard, 1.5× In for 60 s high overload, and 1.85× In for 3 s high overload. The standard overload profile suits variable-torque loads like centrifugal pumps and fans; the high overload profile covers constant-torque loads such as conveyors or extruders that need higher starting torque.

Input topology and harmonic mitigation

The 36-pulse diode rectifier bridge input inherently cancels the 5th, 7th, 11th, 13th, 17th, and 19th harmonics, keeping total harmonic current distortion (THID) below 5 % at full load without external filters. This meets IEEE 519 requirements for the point of common coupling without additional line reactors or active filters — a significant advantage for installations where utility-imposed harmonic limits are tight. The integrated EMC filter and electrical isolation between power and control circuits further simplify compliance with EN/IEC 61800-3 (emission and immunity for adjustable-speed drives) and EN/IEC 61800-5-1 (safety requirements). The drive carries CE marking.

Protection, isolation, and fault handling

Ground fault protection is integral to the drive. Dielectric strength is 20 kV AC between earth and power terminals. The drive is rated for overvoltage category II per EN/IEC 61800-5-1 and pollution degree 2. Prospective short-circuit current withstand is 31.5 kA for 150 ms — this sets the minimum SCCR for the upstream protective device. Vibration resistance is 4.9 m/s² over 10–50 Hz. Noise level is 80 dB — hearing protection is required within the enclosure vicinity during operation.

Control interface and I/O complement

Four software-configurable analogue inputs accept 0–20 mA or 4–20 mA current signals, 24 V max, 250 Ω impedance. Two analogue outputs are similarly configurable for 0–20 mA or 4–20 mA DC. Six discrete inputs are standard, expandable to ten. The external control supply is 220 V AC, 3 kVA, with an optional 220 V AC/DC supply. Cooling fans draw 380 V AC from an internal supply.

Frequently asked questions

What are the key power ratings for the ATV1200A85506363?

Motor power is 6571 kW, apparent power is 7860 kVA, line current is 720 A, and the supply voltage range is 2970–3630 V. The input is a 36-pulse diode rectifier.

What overload ratings does this drive support?

Standard overload: 1.2× In for 60 s and 1.5× In for 3 s. High overload: 1.5× In for 60 s and 1.85× In for 3 s. The high overload profile is suited for constant-torque loads requiring higher starting torque.

What compliance standards does the ATV1200A85506363 meet?

It complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. It carries CE marking.

MPN
ATV1200A85506363